NDC-F18

Access Control Panel

Installation Manual

NDC-F18

A C C C E S S   C O N T R O L   P A N E L

®

Summary of Contents for NDC-F18

Page 1: ...NDC F18 Access Control Panel Installation Manual NDC F18 A C C C E S S C O N T R O L P A N E L ...

Page 2: ...2 Integrated Technical Vision http www itvsystems com ua ...

Page 3: ...ction of the document or its part without permission of Integrated Technical Vision Ltd is prohibited Trademarks ITV is a registered trademark of Integrated Technical Vision Ltd Training and technical support Integrated Technical Vision Ltd performs training on the installation programming and utilization of NDC F18 access control panel For additional information about training and discussing of y...

Page 4: ...4 Integrated Technical Vision http www itvsystems com ua ...

Page 5: ...m 11 Controls and connections on the board 12 Control Panel Operation 13 Mounting 15 Wiring 16 Readers connection 16 Inputs wiring 16 RTE button 17 Door Contact 17 Door contact and RTE button 17 Free Pass and Blocking 18 Executive devices 18 Locking devices 18 Sirens Bells and agents 19 RS 485 Interface 20 Address settings 21 Limited Warranty 22 ...

Page 6: ...ou sands NDC F18 panel operates as a total stand alone unit with fully distributed database All valid card numbers time zones and relay pulse times are loaded into controller s memory The panel controls access on two access points on a stand alone basis with no dependency on central computer system Control panels are connected via RS 485 dropline in Access Control Systems Features o Supports all W...

Page 7: ...ripple 500 mV 12 V Inputs 8 programmable EOL supervised inputs 2 inputs for battery and power state control Outputs Two 1 A 24 V relays Two 5 A 24 V relays Networking RS232 485 interface Operation temperature 0 С 55 С RelativeHumidity 95 relative at 25 С Nonvolatile memory capacity is shown in the table below Overall dimensions 300х310х80mm Weight 2 45 kg s r o t a c i f i t n e d I 6 9 0 4 s t n ...

Page 8: ...f an attempt of a code or ID matching The Code matching is considered when invalid code or ID entered several times Valid code entrance clears the counter This function switching on and number of code entrances are subjects of programming Door Contact DC In access control systems various sensors are used to supervise the status opened or closed of the pass way magnetic door sensor sensor of the tu...

Page 9: ...than pressing the RTE button by reenergizing locking device opening lock with a key etc the Door Forced Open event arises RTE button may be used for remote door opening as well Schedules NDC F18 is capable to store up to 100 time zones 100 week schedules can be combined from these time zones including 70 holidays Moreover NDC F18 can store several floating schedules based on the period different t...

Page 10: ... of the power supply plate to the control panel base plate is shown on diagram to the right What s inside 1 3 5 220 В 50 Гц 2 6 GND 1D0 1D1 1RD 1GN 1BZ Z1 GND Z2 X1 Z3 GND Z4 9V C3 NO3 C1 NC1 NO1 DCG ACG AC DC X3 ITV NDC F18 S3 S6 B GND EB TMP GND Z6 GND Z5 Z8 GND Z7 2GN 2RD 2D1 2D0 GND 2BZ 9V C4 NO4 C2 NC2 NO2 A X2 F16 r5 X5 EXT MODULE IDN RST X4 RS232 4 p r im a r y w in d in g s e c o n d a r y...

Page 11: ...ed Door contacts RTE buttons Free Pass buttons Blocking buttons Output of power supply with direct or alternate current protected against overvoltage and crosspolarity Up to two Wiegand readers GND 1RD 1GN 1B Z1 GN Z2 X Z3 GN Z4 9V NO3 C1 NC1NO1 DCACG AC X3 ITV NDC F18 S3 S6 B GN D EB TM P GND Z6 GND Z5 Z8 GND Z7 2GN 2RD 2D1 2D0 GND 2BZ 9V C4 NO 4 C2 NC 2 NO2 A X2 F16 r5 X5 EXT MODULE IDN RST X4 R...

Page 12: ...l p p u s r e w o P W P G d o o g r e w o p 0 2 2 3 X C D C A r e w o P y l p p u s r e w o p e t a n r e t l a r o t c e r i D n o i t c e n n o c 2 X A A 5 8 4 S R e n i l p o r d 5 8 4 S R B B 5 8 4 S R D N G D N G B E r e w o p s e c i v e d l a n o i t i d d A P M T P M T n o i t c e n n o c r e p m a T D N G D N G 2 O N n e p o y l l a m r o N s l a n i m r e t 2 y a l e R 2 C N d e s o l c ...

Page 13: ...ings downloading The panel can be turned to unloaded status only with command from PC see programming instruction The panel can control two independent access points Each access point may be in one of the four modes main mode alarm blocked or free pass Free pass mode has the highest priority as panel switches to this mode in case of fire then blocked alarm and main modes follow Main Mode Panel gra...

Page 14: ...ches reader s red LED and buzzer for 1 second Lost or Blocked ID passed on ID passing panel switches reader s red LED and buzzer for 1 second Access point is in alarm mode reader s red LED lights constantly Access point is in blocked mode reader s red LED lights constantly Alarm Mode In alarm mode reader s red LED lights constantly Access point goes into alarm mode for following reasons In case of...

Page 15: ...ted to cardholders of IDs with Security Service sign Door cannot be unlocked with RTE button When access point is in blocked mode reader s LED blinks red and green alter nately Access point switches into blocked mode by operator s command or when input programmed as BLOCKING is open Access point remains in blocked mode until this input is open or until operator cancels the mode Mounting NDC F18 is...

Page 16: ...LED black GND red 9V The wires colors can differ in readers from other vendors Please refer to reader s Installationmanual Inputs wiring NDC F18 has eight EOL inputs All inputs are programmable Their functions are set duringprogramming The possible inputs functions are door contact RTE button door contact and RTE button free pass A B A B blocking A B A B state monitoring 2GN 2RD 2D1 2D0 GND 2BZ 9V...

Page 17: ...ched inputs as RTE button inputs Door Contact Door state opened or closed is determined by the status of door contact If door contact is not connected the panel is not able to determine the events of door force or not closed door The wiring of door contacts normally closed to Z3 and Z7 terminals is shown on wiring diagram So that door contact could work properly set attached inputs as door contact...

Page 18: ...osed contacts rating 5 A 24 V Relay 3 and 4 have normally open contacts rating 1A 24V Do not use diodes when executive devices are attached to alternate current net When selecting power supply for the control panel mind that its capacity should correspond to power consumption of the control panel and executive devices Locking devices NDC F18 has two relay outputs with form C contacts The operation...

Page 19: ...on power of the bell should not exceed 1A Some sirens require polarity observing Often Electric bells are the inductive load for power supply Connecting the bells observe the warning about the inductive load above So that the siren could work properly set attached relay output as siren output while programming Bell up to 24V 1А GND C4 NO 4 C2 NC 2 NO2 Wiring ...

Page 20: ...ng For maximal range of 1200 meters please use 0 4 mm2 cross section wire 0 2 mm2 cross section wire will provide the range of 500 meters On the first and the last panel in the dropline short jumpers S3 S4 and S6 which connect loading resistors Take care of proper grounding of all panels in the network RS485 cables are connected to A and B GND and EB contacts Connect wires of one color always to t...

Page 21: ...st have the unique address from 0 to 31 To adjust the panel address use the S2 jumpers set jumper is shorted Jumper is open Address settings s s e r d d A s r e p m u J 6 2 S 5 2 S 4 2 S 3 2 S 2 2 S 1 2 S 0 1 2 3 4 5 6 7 8 9 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 0 3 1 3 ...

Page 22: ...oltage mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be lieu of any and all other warranties whether expressed or implied and of all other obligations or liabilities on the part of Integrated Technical Vision Ltd This warranty contains the entire warrant...