    HOW TO CLEAN THE NOZZLES IN THE NDP55 

 

 

STEP 3: Remove the nozzles one by one, by pulling them out of the metallic collector, 
and clean them. Also, clean the metallic filter. 

                  

                

 

 

 

 

STEP 4:  Put the nozzles in place (keep in mind the position, same one, and always the 
L shape towards the front door, as the next picture. 

   

 

 

STEP 5: Assemble everything backwards, please remember that the collector must fit 
tight  in place, the plastic pipe  has to fit the hole. And please place the metallic filter 
correctly, tight so it does not move while working. 
 
Next you have some pictures of the correct spray pattern. If some nozzle does not spray 
upwards and in line, use a flat head screw driver and use it to fit in inside the line of the 
nozzle to open it a little bit so it releases the scale inside. 

 