ENGLISH
8
4.
CONTROL PANEL
The outer panel is located at the front of the machine, in the upper left corner and has 5 buttons:
4.1. PE1.- ON/ OFF BUTTON
When turning on the rear switch of the machine, PE1 will be red, which means that the machine will be in the stand by mode. Pressing
the PE1 button will enter the timing state and the LED will light up with a flashing blue. After the time period elapses, the LED will remain
steady blue and the machine will start to work. If an alarm is detected in the machine, press the button for more than 3 seconds and the
machine will restart.
4.2. PE2.- RESERVOIR FULL
This LED will light up when the machine has stopped when the reservoir is full.
4.3. PE3.- GEAR MOTOR ALARM
This alarm has two states.
In the first, the LED will remain flashing and the machine will perform a timing and will automatically resume. The machine will continue
to operate in this state.
In the second state, the LED will remain steady and the machine will be stopped until a reset is performed.
4.4. PE4.-INTERNAL FAULT ALARM
This LED will remain on when an internal fault has occurred in the machine, or a blockage has occurred in the outlet. With this alarm,
the machine will remain stopped.
4.5. PE5.- LACK OF WATER SUPPLY ALARM
This LED indicates that there is no water supply and therefore the machine is stopped because it cannot manufacture ice.
PE1
PE2
PE3
PE4
PE5