Enclosure 6N Pressure Switches
Page 14
Weather Proof Ratings
Ingress protection IP66
Enclosure type 3, 3R, 3S, 4, 4X, 13 (NEMA)
Temperature Ranges for Pressure Media
Standard (Nitrile O-rings, -40°C (-40°F) to +121°C (+250°F) and Wetted Matl. 5-7, 9);
C Option (EPR O-rings):
-40°C (-40°F) to +121°C (+250°F) and Wetted Matl. 5-7, 9);
B Option (Viton O-rings): -26°C (-15°F) to +121°C (+250°F) and Kalrez O-rings
Electrical and Ambient Temperature Ratings
Minimum ambient temperature is -40 °C (-40 °F),
except with B Option and Kalrez O-rings it is -26°C (-15°F)
Form C6N (SPDT):
11 amp @ 125 or 250 VAC to +70 °C (+158 °F) max, T5;
11 amp @ 125 or 250 VAC to +60 °C (+140 °F) max, T6;
5 amp @ 125 or 250 VAC 5; amp resistive , 3 amp inductive @ 28 VDC; .5 amp
resistive, .04 amp inductive @ 125 VDC to +70 °C (+158 °F) max, T6.
Form CC6N (DPDT):
11 amp @ 125 or 250 VAC to +65 °C (+149 °F) max, T4A;
11 amp @ 125 or 250 VAC to +45 °C (+113 °F) max, T6;
5 amp @ 125 or 250 VAC; 5 amp resistive , 3 amp inductive @ 28 VDC; .5 amp
resistive, .04 amp inductive @ 125 VDC to +70 °C (+158 °F) max, T6.
Form C6MN or CC6MN (SPDT or DPDT with M Option):
1 amp @ 125 VAC to +70 °C (+158 °F) max. T6