Enclosure 6N Temperature switches
Page 9
Wetted Materials
Table 1
No
Description
3 300-series CRES with Viton seal, except Teflon seal on Range J (Model 100T)
5 300-series CRES with graphite-filled non-asbestos packing (Model 100TC)
Weather Proof Ratings
Ingress protection IP66
Enclosure type 3, 3R, 3S, 4, 4X, 13 (NEMA)
Pressure Ratings
Maximum Operating Pressure: 1500 psig (103.5 bar)
Proof Pressure: 2250 psig (155.1 bar)
Electrical and Ambient Temperature Ratings
Minimum ambient temperature is -40 °C (-40 °F),
Form C3X (SPDT):
15 amp @ 125 or 250 VAC , 1/8 HP @ 125 VAC,
¼ HP @ 250 VAC, to +70 °C (+158 °F) max;
5 amp resistive , 3 amp inductive @ 28 VDC; .5 amp resistive , .04 amp inductive @ 125
VDC to +85 °C (+186 °F) max.
Form CC3X (DPDT):
11 amp and ¼ hp @ 125 or 250 VAC to +65 °C (+149 °F) max;
5 amp resistive , 3 amp inductive @ 28 VDC; .5 amp resistive @ 125 VDC to+85 °C
(+186 °F) max.
Form C3MX or CC3MX (SPDT or DPDT with M Option):
1 amp @ 125 VAC to +85 °C (+186 °F) max.
Form Z3X (SPDT):
15 amp @ 125 or 250 VAC , 1/4 HP @ 125 VAC,
1/2 HP @ 250 VAC, to +80 °C (+176 °F) max;
5 amp resistive , 3 amp inductive @ 28 VDC; 1 amp resistive , .5 amp inductive @ 125
VDC to +85 °C (+186 °F) max