ITT NEO-DYN 100T Installation And Operation Manual Download Page 11

 

Enclosure 6N Temperature switches

Page 8

  

CHAPTER 

SPECIFICATIONS 

This section shows standard specifications and available options. 

STANDARD 

Interfaces 

Weight: approximately 3 pounds (1.4 kg) each 

Conduit Connection: ½” - 14 NPT male 

Standard Pressure Port Connection:  ½” - 14 NPT female 

Listing Agency Approvals 

CE Mark 

All models with option letter X in the part number. 

Internal switching elements are recognized components by both UL and CSA. 

Part Number 

The part number contains information about which configurations and options are 

included in your Adjustable Temperature switch. To determine the pressure range, 

electrical rating, and options, compare the part number of your unit with the information 

in Figure 4 and Table 1. 

 

Figure 4.. Part Number Breakdown 

NOTE:

  Part number format varies for specials. 

 

 

Summary of Contents for NEO-DYN 100T

Page 1: ...NEO DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL PN 610 0012 Rev C...

Page 2: ...al injury death or substantial property damage if the warning is ignored CAUTION Indicates a hazard which will or can cause minor personal injury or property damage if the caution is ignored SPECIAL C...

Page 3: ...FIGURATIONS 2 CHAPTER 2 INSTALLATION 3 MOUNTING 3 PROCESS CONNECTIONS 4 PROCESS MEDIA 4 POTENTIALLY EXPLOSIVE ATMOSPHERES HAZARDOUS LOCATIONS 4 ELECTRICAL CONNECTIONS 5 CHAPTER 3 ADJUSTMENTS AFTER INS...

Page 4: ...Model 100TC has a graphite filled non asbestos packing Setpoint adjustments are easily made through the adjustable range by turning an adjustment nut located inside the housing The standard configurat...

Page 5: ...n or our representatives in several ways The Neo Dyn customer service phone number is 661 295 4000 Our customer service department is open from 7 00 am to 3 30 p m Pacific Time Our Internet site is ww...

Page 6: ...MOUNTING Model 100T can be mounted directly to the process connection if there is no significant vibration and the fluid lines are capable of supporting the weight It can also be attached to a flat su...

Page 7: ...ling compound CAUTION Avoid excessive torque on all threaded connections WARNING Do not exceed the marked maximum operating pressure in normal operation WARNING Do not use as a safety device The marke...

Page 8: ...uirements of the NEC or applicable local or national electrical codes including wire gauges and insulation temperature ratings Conduit seals may be required Figure 2 Form C and CC Schematics Shown Bel...

Page 9: ...below 4 To check the increasing setpoint of a temperature switch insert the temperature probe into a fluid bath so that the hex is within 3 8 inch 9 5 mm of the surface and also insert a calibrated th...

Page 10: ...ng can be heard to audibly snap but an ohmmeter indicates no electrical switching the cause is probably stuck or burned switch contacts or the switch element has moved away from the position where it...

Page 11: ...ls CE Mark All models with option letter X in the part number Internal switching elements are recognized components by both UL and CSA Part Number The part number contains information about which conf...

Page 12: ...rature Ratings Minimum ambient temperature is 40 C 40 F Form C3X SPDT 15 amp 125 or 250 VAC 1 8 HP 125 VAC HP 250 VAC to 70 C 158 F max 5 amp resistive 3 amp inductive 28 VDC 5 amp resistive 04 amp in...

Page 13: ...rd switches are listed below These options can be combined every included option will be indicated in the part number of the unit Table 2 Option Description A Epoxy painted exterior M Gold Electrical...