Clamp-on ammeter
Voltmeter
A good grade of pipe joint compound should be available to facilitate assembly and possible fu-
ture disassembly.
4.
Installation equipment
Although portable derricks are sometime used, a properly designed pump setting rig is recom-
mended. It must be possible to erect the crown block to a height so as to allow the load hook to
be raised about three feet higher than the longest piece. The lifting device must be of sufficient
strength and rigidity to raise the total weight of the unit safely.
CAUTION:
Remember-regardless of the type of lifting equipment, or the type of pumping equipment, the
primary rule is: safety first.
2.3
Materials and Equipment Required
VIS Installation, Operation and Maintenance Instructions
11
Summary of Contents for Goulds Pumps VIS
Page 1: ...Installation Operation and Maintenance Instructions VIS ...