15. Select an appropriate length gauge bar to match pump features, measure height and record as di-
mension "H".
16. If using ITT/GOULDS gauge bar K14153A kit proceed to Step 20.
NOTICE:
K14153A is a set of gauge bars designed to fit within the gasket sealing feature of ICO casings
but is not a required tool.
Figure 45: Goulds gauge bar method
Figure 46: Generic gauge bar method
17. Measure from top of bar to impeller (230) back hub face as shown in
and record in A1 field.
18. Measure from top of bar to casing (102V) gasket surface as shown in
and recorded in A2 field.