412A
Figure 56: O-ring for model CV 3196
If the impeller cannot be removed by the previous methods, cut the shaft between the gland and the
frame, remove the impeller, stuffing-box cover, gland, sleeve, and shaft end as a unit. Do not apply heat.
6.4.8 Shaft guard removal (if provided)
6.4.8.1 Remove the shaft guard (STi)
1.
Remove the bolt for each shaft guard half that mounts the halves to each side of the frame.
2.
Do not remove the clip that retains the bolt on the guard to maintain a captive fastener.
3.
Retain each guard half with fasteners for reinstallation.
1
2
Item
Description
1.
Retaining clip (do not remove)
2.
Mounting bolt
Figure 57: Shaft guard installation
6.4.8.2 Remove the shaft guard (MTi/LTi, XLTi/i17)
1.
Remove the bolt for each shaft guard half that mounts the halves to the brackets on each side.
2.
Do not remove the clip that retains the bolt on the guard half to maintain a captive fastener.
3.
Do not remove the brackets from each side of the frame adapter.
6.4 Disassembly
Model CV 3196 i-FRAME Installation, Operation, and Maintenance Manual
83