Maintenance
Model API 3171 Installation, Operation, and Maintenance Manual
43
Drain the pump
CAUTION:
• Risk of physical injury. Allow all system and pump components to cool before handling.
• If the pumped fluid is non-conductive, drain and flush the pump with a conductive fluid
under conditions that will not allow for a spark to be released to the atmosphere.
1. Leave the drain valve open.
Do not close the drain valve until the reassembly is complete.
2. Remove the coupling guard.
3. Disconnect the coupling.
Remove the pump from the sump
1. Remove the motor bolts (371).
Figure 16: Motor bolts removal
2. Place the sling on the motor lifting lugs and remove the motor.
3. Remove the support plate anchor bolts.
4. Attach the eyebolts to the support plate.
5. Use properly-sized slings in order to lift the pump from the sump.
Refer to the Installation chapter for the proper handling procedure.
6. Lay the pump horizontally on proper supports where there is sufficient clearance to
disassemble the pump.