Figure 4: Example of a proper lifting method
NOTICE:
Do not use this method to lift a Polyshield ANSI Combo with the pump and motor mounted.
These items are not designed to handle the heavy weight of the Polyshield system. Doing so
may result in equipment damage.
Figure 5: Example of a proper lifting method
NOTICE:
When lifting a unit for which a strap cannot be secured at the suction flange, secure the strap
through the frame/frame adapter. Securing at the frame adapter will prevent slipping of the
strap and possible equipment damage.
2.1.3 Storage guidelines
2.1.3.1 Pump storage requirements
Storage requirements depend on the amount of time that you store the unit. The normal packaging is
designed only to protect the unit during shipping.
Length of time in storage
Storage requirements
Upon receipt/short-term (less than six
months)
•
Store in a covered and dry location.
•
Store the unit free from dirt and vibrations.
Long-term (more than six months)
•
Store in a covered and dry location.
•
Store the unit free from heat, dirt, and vibrations.
2.1 Transportation and Storage
3175 Installation, Operation and Maintenance Instructions
13