TROUBLESHOOTING GUIDE

 

 

Symptom

:  Outlet pressure continues to rise after flow 

ceases. 
 

Potential Cause

:  Valve seat leakage 

Repair

:  Disassemble and clean regulator 

components.  Install new valve plug and filter element 
(if applicable). Reassemble. 
 

Symptom

:  External leakage 

 

Potential Cause

:  Diaphragm to body joint seal 

leakage. 

Repair:

  Disassemble.  Inspect regulator body where 

diaphragm seals.  Replace diaphragm assembly. 
 

Potential Cause

:  Bowl to body joint leakage. 

Repair:

  Disassemble.  Inspect regulator body where 

bowl o-ring contacts.  Inspect bowl where o-ring 
contacts.  Replace o-ring.

  

 
 
 
 
 

 
 
 
 
 
 
Symptom

:  External leakage 

 

Potential Cause

:  Draincock leakage. 

Repair:

  Tighten draincock by turning handle 

clockwise. 

 
Symptom

:  Outlet pressure cannot be adjusted to 

maximum control range. 

Potential Causes: 

1.  Control knob positive stop adjustment. 
2.  Flow induced droop. 

Repair:   

1.  Adjust positive stop of control knob.  
2.  A higher output range regulator may be required. 
 

Symptom:

  Noisy operation. 

 

Potential Causes:

 Turbulence in adjacent piping. 

Repair: 

Insure that there are no elbows, line tees or 

other turbulence creating piping directly upstream or 
downstream of the pressure regulator. 

 
 

Summary of Contents for GFH45

Page 1: ...STRUCTION Nozzle Assembly Brass with Buna N Soft Seat Range Spring Zinc Plated Carbon Steel Diaphragm Assembly see CED Code Bowl Brass Body Brass Bonnet Brass SPECIFICATIONS Maximum Supply Pressure 300 psig 2 07 MPa Outlet pressure ranges are determined by the last character in the regulator model number C 25 psig 172 kPa F 60 psig 414 kPa G 125 psig 862 kPa Proof Pressure 150 of maximum operating...

Page 2: ... factory plugged outlet gauge ports WARNING If the supply line is connected to the outlet port regulator damage or unexpected flow through the regulator could occur Prior to applying inlet pressure double check the connections and assure the wrench knob or hand wheel is backed out sufficiently to unload the range spring in the bonnet Carefully apply inlet pressure and check the supply connection f...

Page 3: ...leed No Relief Character 10 Gauge Selections X No Gauge standard Character 11 Filter Bowl Option 1 Standard Bowl Size NOTE Materials of construction and cleaning specifications are the user s responsibility Character 12 Control Ranges C 25 psig 172 kPa F 60 psig 414 kPa G 125 psig 862 kPa OPERATION IN SERVICE Open upstream controls to provide the regulator supply pressure To increase the output se...

Page 4: ...kage Repair Disassemble Inspect regulator body where bowl o ring contacts Inspect bowl where o ring contacts Replace o ring Symptom External leakage Potential Cause Draincock leakage Repair Tighten draincock by turning handle clockwise Symptom Outlet pressure cannot be adjusted to maximum control range Potential Causes 1 Control knob positive stop adjustment 2 Flow induced droop Repair 1 Adjust po...

Page 5: ...r 9 Remove the dripwell by pulling downward away from the body 10 Remove the filter 11 To remove the plug spring and valve plug unscrew the retainer then grip the plug spring and pull downward away from the body The plug and plug spring should slide out of the body together ASSEMBLY 1 Replace worn or damaged components with new components 2 Clean and inspect components for reuse Sealing surfaces m...

Page 6: ...or Model Number and Item Description This will permit positive identification and rapid handling of order 2 Spare parts kit standard configuration only a G6385516 for the 0 25 60 psi 172 414 kPa models b G6385517 for the 0 125 psi 862 kPa model 3 For other model configurations or non CED codeable models consult factory for correct part number ...