Supply
~1
×
230 V
Back-up fuse
16 A
5.2 Connecting diagram in standard model
Take the pump off power (OFF)
before the switch settings are changed.
Connecting diagram:
10-11
Control contact
to switch the pump on
and off externally.
(Contact open = pump ON,
contact closed = pump OFF)
10-13
Control contact
to switch the minimum
speed on and off externally.
(Contact closed
= minimum speed ON)
51-54
Error message
(potential-free closing
contact closed if there
is a malfunction),
contact load
max. 250V~, 1A
61-64
Operating message
(potential-free closing
contact closed during
operation), contact load
max. 250V~, 1A
71-72
Analogue input 0 to 10
V or 0 to 20mA
when setting the speed
externally.
See point 5.3
(A)
Additional strain relief
for clamps 10-13, 10-11,
71-72, 61-64