Operating manual VK 30.03 

 

2.2 

User’s responsibility 

The  material  selection  switch  may  only  be  used  when  it  is  in  perfect 
working condition. 
 

2.3 

Safety requirements 

The instrument works with an operating voltage of 24 VDC. The voltage re-
quired  for  operation  must  be  supplied  by  a  separate  power  supply.  This 
power supply unit must conform to directive IEC 61010

 

2.4 

Radio interference suppression / EMV 

The  instrument  complies  with  the  requirements  of  EC  Directive 
89/336/EEC changed by 91/263/EEC; 92/31/EEC; 93/68/EEC relating to 
radio interference suppression and electromagnetic compatibility.  
 
European certification:  

 

 

EN 61000 - 6 - 4  

 

 

 

 

 

 

 

EN 61000 - 6 - 2  

 

 

 

 

 

 

 

EN 55011  

 

 

 

 

 

 

 

 

 

When connecting a power supply unit, make sure that is also conforms 
to  these  standards.  Radio  interference  may  arise  if  the  pyrometer  is  in-
terconnected with such peripheral devices which have not been properly 
interference-suppressed.  This  may  necessitate  additional  interference 
suppression measures.  
 

2.5 

Quality Management Certification 

The KELLER HCW Quality Management System meets the DIN EN ISO 
9001  standards  for  design,  production,  repairs  and  service  for  non-
contact infrared temperature measuring equipment. 

 

 

  

 

 

2.6 

Environmental Management 

Sustainable economic management is more important than ever.  
KELLER HCW’s corporate environmental management system complies 
with DIN EN 14001/50001 standards. 
 

 

Summary of Contents for VK 30.03

Page 1: ...Operating manual VK 30 03 Material selections switch VK 30 03 Ident No 109 8756 12 2018...

Page 2: ...suppression EMV 3 2 5 Quality Management Certification 3 2 6 Environmental Management 3 3 General 4 4 Connection 4 4 1 Connection plan 4 4 2 Current output 4 20 mA 4 4 3 Parameterization VK 30 03 6 5...

Page 3: ...and or material damage CAUTION This symbol indicates important information which if neglected might result in material selection switch damage malfunction or breakdown PLEASE NOTE This symbol points o...

Page 4: ...pproval of the Manufacturer are expressly prohibited by law Violations shall be subject to compensation claims by the Manufacturer The right to claim additional indemnities remains reserved 2 Safety T...

Page 5: ...ic compatibility European certification EN 61000 6 4 EN 61000 6 2 EN 55011 When connecting a power supply unit make sure that is also conforms to these standards Radio interference may arise if the py...

Page 6: ...tage required for operation must be supplied by a separate power supply This power supply unit must conform to directive DIN IEC 61010 3 GND current output 4 0 4 20 mA 12 Power supply 24 DC 13 Power s...

Page 7: ...Operating manual VK 30 03 5 Pyrometer PA PIN 3 GN green Analogue output 2 analogue input PIN 8 RD red L GND VK 30 03 Clamp 4 Current output Clamp 3 L GND...

Page 8: ...ues use the arrow keys and Configuration of the analogue output Use the keys and to select 4 20 mA Set point for power on rEStor set Point value remains valid in case of power failure Selection with t...

Page 9: ...Q emissivity ratio AI U1 Ain Scaling Define lower limit of voltage for input voltage 2 V AI U2 Ain Scaling Define upper limit of voltage for input voltage 10 V AI V1 Ain Scaling Input of lower voltag...

Page 10: ...g claims has expired you will no longer be able to make any claims for compen sation of damage or loss 6 2 Packaging The packages used by KELLER HCW are made of carefully selected environmentally comp...

Page 11: ...Operating manual VK 30 03 9...

Page 12: ......

Reviews: