AC Heat LED (Green)
•
Not used.
Compressor, Fuel Pump, Combustion Fan, Igniter LED
(Green)
•
The air Compressor, Fuel Pump, Combustion Fan and
Igniter LEDs (green) turn ON when the component is
ON, and will flash if the component is electrically
open or shorted.
Flame Out LED (Red)
•
The Flame Out fault LED (red) turns ON when a flame
fault has been detected.
Voltage LED (Red)
•
The Voltage fault LED (red) turns ON when a voltage
fault has been detected.
Low Water LED (Red)
•
The Low Water level fault LED (red) turns ON when a
low water level in the WindowWasher™ has been
detected.
7.6
WindowWasher Maintenance
Customer Monthly Maintenance: Check the following and
correct as required:
Water hoses and fittings for leaks and integrity.
Exhaust fittings, connections, tubes for leaks, and integrity.
Exhaust and air-intake checked for no obstructions.
Fuel lines, fittings for leaks and integrity.
External fuel filter for clogging.
Annual Factory Maintenance: Perform the following:
Factory Service Tune-up (DC power is disconnected):
Prior to operation for the season, a factory service tune-up of
the modular system should be performed by trained service
personnel. Only personnel familiar with the equipment
modules should perform the service tune-up. It is
recommended that the dealer be contacted for this service or
if not available, contact Calcutt Boats or ITR for further
instructions.
As a general guide, the regular maintenance items such as
the igniter, fuel nozzle, fuel filters (internal and external) and
air filter (internal) should be replaced as opposed to
inspected and cleaned. Their performance may be