Section 5, Installing Fan Heaters
5-2
Installation Manual for Hurricane® Zephyr™ HW Heating System
5.2
Fan System Operation
ITR fans consist of a 12 VDC brushless fan and heater coil
similar to a radiator.
When the heating fan comes on, the fan draws ambient air
from the interior, blows it across the heater coil and back
into the interior through a vent. The movement of air into
and out of the fan must not be obstructed. Reducing the
supply air (draw) to the fan will proportionality reduce the
flow of heated air.
Features
·
ITR heating fans can be supplied with an aquastat, which
prevents the fan from operating and blowing cold air when
the system heat transfer fluid is below 120°F (49°C).
Figure 5-1 shows how to wire up the aquastat.
Figure 5-1: Wiring the Fan’s Aquastat
·
If a “passive” radiant heat system is desired (i.e.
baseboard or fin and tube configurations), consult ITR
for recommended installation procedures and design.
Multiple Zone Heating
Up to four thermostats (positive DC compatible) can be
installed to allow separate temperature regulation of the four
zones. The Zone control board has an 18-amp draw limit for
all the fans and the internal pump. Note: the internal pump
of Hurricane® Zephyr™ HW will draw approximately 2.5
amps.
Summary of Contents for Hurricane Zephyr HW
Page 14: ...Section 1 Overview 1 8 Installation Manual for Hurricane Zephyr HW Heating System...
Page 20: ...Section 2 Mounting the Heater Unit 2 6 Installation Manual for Hurricane Zephyr HW Heating...
Page 43: ...Section 6 Wiring the Electrical System International Thermal Research 6 9...
Page 83: ...Section 11 Maintenance 11 6 Installation Manual for Hurricane Zephyr HW Heating System...
Page 88: ...International Thermal Research Warranty Information International Thermal Research Page 5...
Page 89: ...Warranty Information International Thermal Research Page 6 International Thermal Research...