5.1. INSTALLATION OF THE RECEIVER 

The receiver should be installed in an accessible location to be able to work on it easily. 

Please  note  in  compliance  with  RD  171/2004  on  the  Coordination  of  Business  Activities,  that  you  must 
guarantee  the  security  conditions  for  the  maintenance  of  the  machine  in  question,  especially  in  its 
accessibility and transit areas up to the points where the operator must do their job.

 (1)

 

 

¡ATTENTION!:

 IT IS VERY IMPORTANT TO CLOSE THE RECEIVER COVER 

PROPERLY IN ORDER TO ENSURE ITS WATER TIGHTNESS, SINCE THE INLET OF 
WATER CAN DAMAGE IT. THE GUARANTEE DOES NOT COVER THE DAMAGES 
CAUSED FROM THE INAPPROPIATE CLOSING OF THE COVER. 

 

In  applications  with  an  exterior  antenna,  it  should  be  free  of  metal  shields  in  order  to  achieve  a  better 
radio link and avoid failures in communication. 

5.1.1. FASTENING OPTIONS 

 

 

 

For the magnetic fastening option, it should be placed on a metal surface with a MINIMUM THICKNESS 
of 4 mm, in which the two magnets make contact in all their area with the surface  

Due to the magnetic force of the magnets, to dismantle the set, lever with a flat screwdriver between the 
metal structure of the machine and the magnetic fastening 

 

¡ATTENTION!:

 ONCE INSTALLED, CHECK THAT THE RECEIVER  IS FIRMLY 

ANCHORED AND IT DOES NOT SLIDE 

 

 

5.2. CONNECTING 

It  is  recommended  to  connect  the  equipment  with  a  standard  multi-cable  hose.  This  hose  will  be 
connected to the equipment at one end using the supplied Itowa terminal strip, while a multi-pin connector 
will  be  placed  on  the  other,  identical  to  the  one  used  in  the  machine  to  connect  it  to  your  conventional 
pushbutton box. 

 

 

 

 

                                                      

1

 

Only

 

applicable in Spain

 

Magnetic fastening 
(optionally) 

Summary of Contents for IT3R10

Page 1: ...User Manual MARI10EN Rev 1 05 2020 Receiver IT3R10 EN nS...

Page 2: ...RODUCE THIS MANUAL WITHOUT THE PRIOR WRITTEN AUTHORISATION FROM ITOWA IN THE EVENT OF INFRINGEMENT ITOWA RESERVES THE RIGHT TO TAKE THE ACTION IT DEEMS NECESSARY IN ACCORDANCE WITH THE CURRENT LAW ITO...

Page 3: ...RECEIVER 5 4 TECHNICAL SPECIFICATIONS 6 5 INSTALLATION AND START UP 7 5 1 INSTALLATION OF THE RECEIVER 7 5 1 1 FASTENING OPTIONS 7 5 2 CONNECTING 7 5 3 START UP 9 6 MAINTENANCE 10 6 1 MAINTENANCE OF...

Page 4: ...y and at random thereby avoiding interferences which could cause continuous downtimes during operation The receiver works in the UHF band at frequencies between 433 050 and 434 775 MHz or between 868...

Page 5: ...for each operation of the crane FM radio modulation and FFSK coding are used for radio transmission of control signals The control module is in charge of verifying that the information received is fr...

Page 6: ...2 A to 250 Vac or 30 Vdc Power supply according to the model 48 Vac 230 Vac 20 15 according to EN 60047 5 1 48 Vac 115 Vac 20 15 seg n EN 60047 5 1 115 Vac 230 Vac 20 15 seg n EN 60047 5 1 24 Vac 230...

Page 7: ...na it should be free of metal shields in order to achieve a better radio link and avoid failures in communication 5 1 1 FASTENING OPTIONS For the magnetic fastening option it should be placed on a met...

Page 8: ...ATION AT TERMINALS 24 AND 26 1 This relay can be configured as N C Normally Close through the bridge located on the back of the board 2 For other power supplies please see the attached documents provi...

Page 9: ...lowing steps will be done with the transmitter associated with the receiver Insert a charged battery into the transmitter set release the STOP BUTTON and press the START 1 button The remote control wi...

Page 10: ...BEFORE HANDLING THE TRANSMITTER TURN OFF THE GENERAL SWITCH OF THE MACHINE 6 1 MAINTENANCE OF THE RECEIVER During maintenance of the receiver the following parts will be checked The connection between...

Page 11: ...rting with LED S1 with the first digit of the code reading from left to right The following table indicates the correspondence between the hexadecimal value of each digit and the number of flashes tha...

Page 12: ...STATE LED S2 Stand by mode or operation without changes Fault in Stop relays Flashing for each change of state in one of the relays STATE LED S3 Not used STATE LED S4 EEPROM Ok Error in EEPROM STATE...

Page 13: ...to the electrical panel of the machine using the corresponding connectors The set is connected to the machine but it does not work The power supply of the set is under 45 of the nominal value The set...

Page 14: ...ns avoiding possible negative consequences for the environment resulting from improper disposal And also allows a treatment and recycling of the materials that compose it obtaining important savings i...

Page 15: ...RECEIVER IT3R10 USER MANUAL 15 www itowa com SINDITO S L Faraday 159 08224 Terrassa Barcelona Espa a Tel 34 93 733 98 50...

Reviews: