TROUBLESHOOTING RC-100DX.RC-115DX.RC-137DX
13
Soft Clamp
The clamp pressure when the clamp pedal was depressed can be adjusted.
1
Select the MN mode.
2
Press the CLMP key.
3
The present pressure set value is displayed on the data display unit of
operation panel.
0 (Low) to 9 (High)
4
Adjust the clamp pressure with the keys "+", "-" to define it with the STOR key.
Clamp Hold Circuit
This circuit is the safety circuit for holding the clamp in the present position as it is
where the knife came to an urgent halt in the course of lowering for some reason.
This abnormal condition is reset by main motor stop or pressing the RESET button on
the cutting buttons panel of the main body.
Manual Backgauge Display
Normally, by using the START button with power ON, the backgauge display is made,
but the backgauge can also be displayed even according to the following procedure.
1
Press the STOP key to turn the STOP key LED "ON".
2
Where the present position of the backgauge is at least 40 cm apart from the
knife, pass it through the position 30 cm apart from the knife with the backgauge
FRONT H key.
3
Where the present position of the backgauge is 40 cm Max. apart from the
knife, pass it through the position 30 cm apart from the knife with the backgauge
FRONT H key after moving it to the position at least 40 cm apart from the knife
with the backgauge BACK H.
Counter
The counter counts and stores the frequency of knife operations in memory.
While the key "=" is being depressed, the counts are displayed on the data display unit.