background image

TROUBLESHOOTING

PAPER GUILLOTINE

TYPE

Summary of Contents for Robocut RC-100DX

Page 1: ...TROUBLESHOOTING PAPER GUILLOTINE TYPE...

Page 2: ...peed is low 3 3 The clamp pressure during paper cutting is abnormal 4 4 Pressure set value reference data 4 Knife Drive 5 1 Knife clamp operation is not carried out 5 2 The knife does not operate 5 3...

Page 3: ...Line Adjustment 11 Working Lamp Adjustment 11 Clutch Key Switch Operation 12 The knife is operated manually 12 Soft Clamp 13 Clamp Hold Circuit 13 Manual Backgauge Display 13 Counter 13 Technical Info...

Page 4: ...h is operated and Err 01 is displayed on the operation panel it is considered that the thermal relay for the main motor inside the electric box 2 was actuated Turn the machine power switch OFF and tak...

Page 5: ...9 2 Err is displayed Subsequent to Err 2 digit numerals are displayed This value indicates the error details Err No display Backgauge drive circuit error The backgauge does not operate on page 9 Err...

Page 6: ...switch OFF and after taking safety measures such that the unauthorized person is kept away from the machine contact our service section or local service center 2 The clamp does not lower when the cla...

Page 7: ...g and ensure that the clamp is in normal operation before starting operation Where the faulty place is not known and no restoration is possible turn the machine power switch OFF and after taking safet...

Page 8: ...splay in the semi automatic and full automatic modes are in the proper protrusion arrangement mode the clamp and knife do not operate Ensure that the green LED of the unit receiver and projection unit...

Page 9: ...chine power is turned OFF when the knife started up by pressing the Cutting buttons stopped halfway or where momentary power interruption is considered to have occurred it is necessary to examine the...

Page 10: ...ereby stopping knife operation At this time the clamp hold circuit Clamp Hold Circuit on page 13 is actuated Check the knife supporting bolt and re tighten it Where no product is present in the machin...

Page 11: ...rd the knife comes to an urgent halt This is not a trouble Reset the knife to the uppermost part with a spanner The knife is operated manually on page 12 and after checking the process of product re a...

Page 12: ...djustment is required Contact our service section or our local service center 2 The backgauge does not operate When the power is turned ON display the numerical value indicating the backgauge position...

Page 13: ...r damage 3 Air blow stop control error Air blow and stop of the surface plate air nozzle are controlled with the valve attached between the blower motor blowoff port and surface plate air nozzle Where...

Page 14: ...fe for cutting quality nicked edge and the cutting stick and adjust the knife balance and knife height Cut Line Adjustment Where the cut line is not displayed even when the working lamp switch is oper...

Page 15: ...clutch key switch during main motor operation the main motor starts stop operation and in 120 seconds the clutch is actuated 9 When the STOP key LED on the operation panel goes out no operation is car...

Page 16: ...f the main body Manual Backgauge Display Normally by using the START button with power ON the backgauge display is made but the backgauge can also be displayed even according to the following procedur...

Page 17: ...ric Box 2 Prior to use ensure that the fuse is of the same size and the indication of amperage stamped on the fuse edge agrees to the spare fuse The causes of fuse non conductive state are as follows...

Page 18: ...bnormal load was detected The thermal relay is actuated due to heat After the temperature decreases reset the thermal relay Locate the cause for loading and take adequate measures therefor When the th...

Page 19: ...the like 3 Ensure that the joint surface of rods 1 2 separated due to broken safety bolt is in the parallel state it is necessary to judge whether the rods can be jointed without any gap by machine re...

Page 20: ...ch 2 washers and nuts from top CAUTION 2 safety bolts are provided in one rod Even when either one was broken replace the both in set When no spare is available place an order with our company 10 Ensu...

Page 21: ......

Reviews: