background image

www.itmtools.com.au

5

SAFETY INSTRUCTIONS

Limited Warranty

Industrial Tool & Machinery Sales (hereinafter 
refered to as ITMS) will, within twelve (12) months 
from the original date of purchase, repair or replace 
any goods found to be defective in materials or 
workmanship.
This warranty is void if the item has been damaged 
by accident, neglect, improper service or other 
causes not arising out of defects in materials or 
workmanship. This warranty does not apply to 
machines and/or components which have been 
altered, changed, or modified in any way, or 
subjected to overloading or use beyond 
recommended capacities and specifications. Worn 
componentry due to normal wear and tear is not a 
warranty claim. Goods returned defective shall be 
returned prepaid freight to ITMS or agreed repair 
agent, which shall be the buyer’s sole and exclusive 
remedy for defective goods. ITMS accepts no 
additional liability pursuant to this guarantee for the 
costs of travelling or transportation of the product 
or parts to and from ITMS or the service agent or 
dealer, such costs are not included in this warranty. 
Our goods come with guarantees which cannot be 
excluded under the Australian Consumer Law.
You are entitled to replacement or refund for a 
major failure and to compensation for other 
reasonably foreseeable loss or damage.  You are also 
entitled to have the goods repaired or replaced if 
the goods fail to be of acceptable quality and the 
failure does not amount to a major failure. The 
manufacturer reserves the right to make  
improvements and modifications to design without 
prior notice.

General Safety Instructions

1.

 If an electrical fault is detected or the power 

supply cord is damaged, the device must sent to a 
licenced electrician for repair.

2.

 Guard against electric shock, avoid body 

contact with earthed or grounded surfaces eg. 
pipes, air con, refrigerators etc. 
Never operate the device in rain or wet conditions, 
or if the tool has been exposed to rain or wet 
conditions.

3.

 Power source; ensure that the power source to 

be used conforms to the power requirements 
specified on the name plate.
Ensure the power supply plug matches the outlet. 
Never modify the plug or use adaptors.

4.

 Do not abuse the power cord. Never use the 

cord for carrying, pulling or unplugging the 
device. Keep cord away from heat, oil, sharp edges 
or moving parts. Damaged or entangled cords 
increase the risk of electric shock.

5.

 Extension cord; when using an extension cord 

ensure sufficient thickness and rated capacity.

6.

 The Trademaster fan is suitable for cooling in 

factories, warehouses, workshops and industrial 
work areas. It is not designed for domestic use.

Operating Procedures

1. Oscillating control; 

The oscillating structure is shown in the drawing.  When the oscilate arm is 

secured to the centre bolt hole, the fan will not oscillate.  When oscilate arm is moved to the off-centre 
bolt hole, the fan will oscillate 90 degrees. Always ensure the power is turned off before making any 
oscillating adjustments

5. Fan Direction; 

To change the direction of the fan, turn off the power, loosen the direction-changing 

bolt, adjust the direction of the fan head and tighten the bolt. It is not necessary to move the base of 
the fan.

6. Upward and downward tilt adjustment; 

Turn off the power, hold the head of the fan, loosen the 

connecting bolt and stopping bolt, adjust the fan to satisfactory position and tighten up the two bolts. 
19mm Spanner required ( not supplied )

7. Head Height Adjustment(pedestal type only); 

Turn off the power. Loosen the locking bolt, adjust 

the fan head to ideal position and then tighten up the locking bolt. In order to avoid the fan head 
falling down suddenly, the fan head must be held when the locking bolt is being loosened. 

8. Installation of the wall fan base; 

The angle arm of the fan can be installed facing upwards or 

downwards. In both cases, the longer of the two locking bolts must be inserted through the small hole 
at the end of the angle arm in order to avoid falling off.

9. Speed Adjustment; 

The fan incorporates 3 speed settings which are controlled by the switch on the 

back of the fan head.  “0” represents stop.  “1” is the lowest blade speed setting,  “3” is the highest.

Maintenance

1. Grease change; 

After the fan is operated over 2000 hours (or at least once a year), the grease in the 

gearbox and bearing should be changed.

2. Care; 

If the fan is not used for extended periods, it should be cleaned and put into a dry place. 

PEDESTAL TYPE

WALL TYPE

Phase

1

1

1

Voltage

220-240v

220-240v

220-240v

Power

160w

280w

280w

Part #

TPF24

TPF30

TWF30

Ф

654mm

824mm

824mm

B - C

1235-1760mm

1235-1760mm

-

D

600mm

700mm

-

Spec

TPF24

TPF30

TWF30

Technical Specifications

Installation Dimensions

Limited Warranty

Industrial Tool & Machinery Sales (hereinafter 
refered to as ITMS) will, within twelve (12) months 
from the original date of purchase, repair or replace 
any goods found to be defective in materials or 
workmanship.
This warranty is void if the item has been damaged 
by accident, neglect, improper service or other 
causes not arising out of defects in materials or 
workmanship. This warranty does not apply to 
machines and/or components which have been 
altered, changed, or modified in any way, or 
subjected to overloading or use beyond 
recommended capacities and specifications. Worn 
componentry due to normal wear and tear is not a 
warranty claim. Goods returned defective shall be 
returned prepaid freight to ITMS or agreed repair 
agent, which shall be the buyer’s sole and exclusive 
remedy for defective goods. ITMS accepts no 
additional liability pursuant to this guarantee for the 
costs of travelling or transportation of the product 
or parts to and from ITMS or the service agent or 
dealer, such costs are not included in this warranty. 
Our goods come with guarantees which cannot be 
excluded under the Australian Consumer Law.
You are entitled to replacement or refund for a 
major failure and to compensation for other 
reasonably foreseeable loss or damage.  You are also 
entitled to have the goods repaired or replaced if 
the goods fail to be of acceptable quality and the 
failure does not amount to a major failure. The 
manufacturer reserves the right to make  
improvements and modifications to design without 
prior notice.

General Safety Instructions

1.

 If an electrical fault is detected or the power 

supply cord is damaged, the device must sent to a 
licenced electrician for repair.

2.

 Guard against electric shock, avoid body 

contact with earthed or grounded surfaces eg. 
pipes, air con, refrigerators etc. 
Never operate the device in rain or wet conditions, 
or if the tool has been exposed to rain or wet 
conditions.

3.

 Power source; ensure that the power source to 

be used conforms to the power requirements 
specified on the name plate.
Ensure the power supply plug matches the outlet. 
Never modify the plug or use adaptors.

4.

 Do not abuse the power cord. Never use the 

cord for carrying, pulling or unplugging the 
device. Keep cord away from heat, oil, sharp edges 
or moving parts. Damaged or entangled cords 
increase the risk of electric shock.

5.

 Extension cord; when using an extension cord 

ensure sufficient thickness and rated capacity.

6.

 The Trademaster fan is suitable for cooling in 

factories, warehouses, workshops and industrial 
work areas. It is not designed for domestic use.

Operating Procedures

1. Oscillating control; 

The oscillating structure is shown in the drawing.  When the oscilate arm is 

secured to the centre bolt hole, the fan will not oscillate.  When oscilate arm is moved to the off-centre 
bolt hole, the fan will oscillate 90 degrees. Always ensure the power is turned off before making any 
oscillating adjustments

5. Fan Direction; 

To change the direction of the fan, turn off the power, loosen the direction-changing 

bolt, adjust the direction of the fan head and tighten the bolt. It is not necessary to move the base of 
the fan.

6. Upward and downward tilt adjustment; 

Turn off the power, hold the head of the fan, loosen the 

connecting bolt and stopping bolt, adjust the fan to satisfactory position and tighten up the two bolts. 
19mm Spanner required ( not supplied )

7. Head Height Adjustment(pedestal type only); 

Turn off the power. Loosen the locking bolt, adjust 

the fan head to ideal position and then tighten up the locking bolt. In order to avoid the fan head 
falling down suddenly, the fan head must be held when the locking bolt is being loosened. 

8. Installation of the wall fan base; 

The angle arm of the fan can be installed facing upwards or 

downwards. In both cases, the longer of the two locking bolts must be inserted through the small hole 
at the end of the angle arm in order to avoid falling off.

9. Speed Adjustment; 

The fan incorporates 3 speed settings which are controlled by the switch on the 

back of the fan head.  “0” represents stop.  “1” is the lowest blade speed setting,  “3” is the highest.

Maintenance

1. Grease change; 

After the fan is operated over 2000 hours (or at least once a year), the grease in the 

gearbox and bearing should be changed.

2. Care; 

If the fan is not used for extended periods, it should be cleaned and put into a dry place. 

PEDESTAL TYPE

WALL TYPE

Phase

1

1

1

Voltage

220-240v

220-240v

220-240v

Power

160w

280w

280w

Part #

TPF24

TPF30

TWF30

Ф

654mm

824mm

824mm

B - C

1235-1760mm

1235-1760mm

-

D

600mm

700mm

-

Spec

TPF24

TPF30

TWF30

Technical Specifications

Installation Dimensions

1.  If an electrical fault is detected or the power supply cord is damaged, the device must sent to 

a licenced electrician for repair.

2.  Guard against electric shock, avoid body contact with earthed or grounded surfaces eg. pipes, 

air con, refrigerators etc. Never operate the device in rain or wet conditions, or if the tool has 
been exposed to rain or wet conditions.

3.  Power source; ensure that the power source to be used conforms to the power requirements 

specified on the name plate. Ensure the power supply plug matches the outlet. Never modify 
the plug or use adaptors.

4.  Do not abuse the power cord. Never use the cord for carrying, pulling or unplugging the 

device. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled 
cords increase the risk of electric shock.

5.  Extension cord; when using an extension cord ensure sufficient thickness and rated capacity.
6.  The ITM fan is suitable for cooling in factories, warehouses, workshops and industrial work 

areas. It is not designed for domestic use.

Product dimensions

Part # 

TPF30

TWF30

Ø

810mm

810mm

B - C

1070 - 1250mm

 - 

D

660mm

 -

Reviews: