IMPORTANT!
Never obstruct the unit’s intake grille. All work on the equipment must be
performed cold with the mains power detached. The electrical connection must be fitted
with an efficient earth (ground). Do not place flammable or explosive materials near the
unit. There must be sufficient exchange of air where the unit is installed and no powder
residues, gas or flammable/toxic vapours at high temperatures. Do not fill the fuel tank
while the unit is working; any drips of fuel on the floor must be dried carefully. Make sure
that the fan does not attract papers, cloths, powders or any other material which may
obstruct or damage the unit. Do not start the generator without fuel oil; despite the inter-
vention of the flame control device, the fuel oil pump could grip. Only use the fuel oil indi-
cated on the information plate giving technical data for the machine.
N.B.
Never add petrol or other solvents to approved fuels; when operating at particularly
low temperatures, use fuels with readily available additives.
3
GB
4.1 Electrical Connection
Before starting the unit, make sure that the mains electricity
supply corresponds to the supply value indicate on the label af-
fixed to the machine. - Mains connection must conform to applicable standards, with a
properly functioning earth (ground) connection. Call in a skilled electrician to fit a high
sensitivity differential switch with a 30 mA or lower tripping threshold.
In case of need, it is possible to use feeding cable extension with wire section of 1,5 mm
2
for
lenghts up to 10 mt. and 2,5 mm
²
for lenght between 10 and 30 mt. If the original power supply
cable must be replaced, use a new cable having a suitable crosssection with an earth (ground)
lead; the cable must have a continuous insulating sheath suitable for use both outside and inside;
combustion product discharge must take place in conformity with applicable standards.
CAUTION
5.
START - STOP
When the machine is in normal duty condition the reset button
will turn off. In case of bad working, the reset button will
alight . Please detect and solve the problem causing the failure and reset the machine by
pressing the button.
CAUTION
5.1 Start (without environment thermostat)
- Fill the tank with fuel.
- Insert the plug in the mains socket .
- Place the ignition switch to ON .
The automatic ignition cycle commences, through the control equipment.
After a few seconds of automatic monitoring, the generator begins operating normally.If the unit
comes to a halt because of minor functional irregularities and the RESET PUSH-BUTTON
LED comes ON, press this button to repeat the ignition cycle.