Copyright & Trademarks 

 
Copyright  ©  1999-2017  by  ITL,  LLC.    All  rights  reserved.    This  document  contains 
proprietary  information,  photographs,  graphics,  and  other  material  (collectively,  "the 
Content")  protected  by  copyright,  and  this  manual  and  all  accompanying  hardware, 
software  and  documentation  are  copyrighted.    No  part  of  this  document  may  be 
photocopied or reproduced by mechanical, electronic, or other means in any form without 
written consent of ITL, LLC. 
 

ITL, LLC

 and the 

ITL

 logo are trademarks of ITL, LLC.  All other trademarks and brand 

names are the property of their respective proprietors. 
 

Limited Warranty and Disclaimer 

 
ITL, LLC guarantees that every RLC-200 series controller is free from physical defects of 
material and workmanship under normal use for one (1) year from the date of purchase.  
If  the  product  proves  defective  during  this  warranty  period,  please  contact  ITL,  LLC  in 
order to obtain a Return Authorization Number, RMA. 
 
In  no  event  shall  ITL,  LLC’s  liability  exceed  the  price  paid  for  the  product  from  direct, 
indirect,  special,  incidental,  or  consequential  damages  resulting  from  the  use  of  the 
product, its accompanying software, or its documentation.  ITL, LLC makes no warranty 
or  representation,  expressed,  implied,  or  statutory,  with  respect  to  its  products  or  the 
contents  or  use  of  this  documentation  and  all  accompanying  software,  and  specifically 
disclaims  its  quality,  performance,  merchantability,  or  fitness  for  any  particular  purpose 
unless otherwise stated. 
 
The  technical  documentation  is  being  delivered  to  you  AS-IS.    ITL,  LLC  makes  no 
warranty  as  to  its  accuracy  or  use.    Any  use  of  the  technical  documentation  or  the 
information  contained  therein  is  at  the  risk  of  the  user.    Documentation  may  include 
technical  or  other  inaccuracies  or  typographical  errors.    ITL,  LLC  reserves  the  right  to 
revise or update its products, software, or documentation without obligation to notify any 
individual or entity.   
 
Please send any comments regarding the manual to 

[email protected]

.  

 
 
 

Summary of Contents for RLC-200-UNI

Page 1: ...Toll Free 1 866 624 8309 www itl llc com Installation and Operation Manual RLC 0200 UNI Universal LED Incandescent A 0Controller...

Page 2: ...y period please contact ITL LLC in order to obtain a Return Authorization Number RMA In no event shall ITL LLC s liability exceed the price paid for the product from direct indirect special incidental...

Page 3: ...serious injury and or death Do not attempt to service this equipment with line power applied Do not rely on interlock switches to remove lethal voltages from the system Measure for voltages using a v...

Page 4: ...ent 6 Obstruction Lights 6 Mechanical 6 Electrical 6 Installation 7 Unpacking your RLC 200 Controller 7 Quick Installation Guide 7 RLC 200 Controller Mounting 8 Electrical Connections 9 Connector Desc...

Page 5: ...rsonnel Please take the time to read and familiarize yourself with this manual It contains the information necessary to install test and troubleshoot the RLC 200 Product Description The RLC 200 is cap...

Page 6: ...struction Lights Side Lights Up to Five Incandescent 116W 120 Vac or 100W 230 Vac Up to Five LED ITL MKR LTE1 000 MKR LTE1 0IR or Other 7W LED markers lights Mechanical Dimension Height 12 00 305mm Wi...

Page 7: ...and report any potential shipping damage to the carrier Quick Installation Guide The quick start guide shows how to install the RLC 200 controller Remove RLC 200 controller from packaging material Mo...

Page 8: ...RLC 200 DOC RLC200 MNL Rev8 doc 6 13 2017 Copyright 1999 2017 ITL LLC Page 8 of 15 RLC 200 Controller Mounting...

Page 9: ...P2 and P4 located at the bottom of the controller Connections for alarm relays are made on P5 and P6 located on the right side of the controller Typical connections for a 120VAC system are shown belo...

Page 10: ...or Descriptions Connector Terminals Function P1 L1 N Input Power Line Voltage Input Power Neutral P2 PRI N SEC Primary Obstruction Lights Power Supply Neutral Secondary backup Obstruction Lights P4 BL...

Page 11: ...Operation Setup and operation of the RLC 200 is performed using the Configuration Jumpers Configuration DIP Switches the Marker Alarm Setting dial and the Manual Mode Select Switch Configuration Jump...

Page 12: ...tion Function 1 Transfer Enable ON Transfer Enable OFF Transfer Disable 2 Transfer Alarm ON K7 is Transfer Alarm OFF K7 is Mode Relay 3 Not Used 4 Not Used 5 Not Used 6 Marker Type See Marker Configur...

Page 13: ...l mode This switch should be left in the AUTO position for normal operation In the AUTO position the operating mode is determined by the photoelectric cell Indicator Lights Indicator Lights Descriptio...

Page 14: ...ruction Light Incandescent MKR LTE1 000 L 810 L Obstruction Light LED MKR LTE1 0IR L 810 L Obstruction Light LED with Infrared MKR LTE2 000 L 810 L Double Obstruction Light LED MKR LTE2 0IR L 810 L Do...

Page 15: ...ning equipment for repair and obtain a Return Material Authorization RMA number Revision Description of Change Date Preparer Approval 8 Updated Spare Parts Replacement Parts List Updated Suppression d...