ITI ESL 562 Installation Instructions Manual Download Page 4

4

ESL Smoke Sensor Model 562

Emergencies

Preliminary

7.

Reassemble smoke alarm.

8.

Re-install the batteries.

9.

Attach smoke alarm to mounting ring.

10. Test operation as describe in the “Testing” section.

Servicing

In the event that the smoke alarm needs servicing, send it to: 
Interactive Technologies, Inc., 2266 Second St. North, 
North St Paul, MN 55109.

Emergencies

Develop plans for a variety of emergency situations. 
Periodically discuss and rehearse emergency plans that 
includ the following:

Know the normal stat of doors and windows; open, 
closed, or locked.

Use a different escape rout if closed doors feel hot to 
the touch.

Emphasize that everyone should escape as quickly as 
possible. Do not stop to gather any belongings.

Crawl and hold your breath as much as possible to help 
reduce smoke inhalation during your escape.

Meet at a designated outdoor location.

Emphasize that no one should return to the premises if 
there is a fire.

Notify fire department from a neighbor’s phone.

WARNING

!

If you arrive at the premises and hear sirens, do 
not attemp to enter the building. Call for emer-
gency assistance from a neighbor’s phone.

Floor Plan Example

Figure 9 is an example of a multilevel floor plan. Use it as a 
guide and draw your floor plan on the next page.

Figure 9. Example of a floor plan.

Your Floor Plan

When establishing your excape routes, consider the 
following guidelines:

Show all building levels.

Show all exits, (two exits per room are recommended).

Show the location of all components of the fire system.

Show the locations of any fire extinguishers, hoses, 
ladders, etc.

Living

Room

Dining

Room

Basement

x

H

Hal

l

Bedroom

Bedroom

Living

Room

Recreation

Room

Basement

Hal

l

Bedroom

Bedroom

Living

Room

Dining

Room

Hall

Bedroom

Bedroom

Bedroom

Kitchen

A smoke detector should 
be located on each level.

Smoke detectors should
be located between the 
sleeping area and the rest
of the family living unit.

Living

Room

Bedroom

Bedroom

Bedroom

Dining

Room

Kitchen

TV

Room

In family living units with more
than one sleeping area, locate a 
smoke detector at each area.

H

Summary of Contents for ESL 562

Page 1: ...o add the smoke alarm to panel memory 1 Remove smoke unit from mounting bracket 2 Put the panel in Program Mode Learn Sensors 3 Select a sensor group and sensor number 4 Remove mounting bracket 5 Press and hold the test button 6 The panel will indicate that the sensor has been learned 7 Exit from program mode Note Reinstall smoke unit on mounting bracket Mounting Guidelines Determine the best moun...

Page 2: ...l install on an inside wall between 4 and 6 inches 10 and 15 cm from the ceiling see figure 5 Put smoke alarms at both ends of a bedroom hallway if the hallway is more than 30 feet 9 meters long Large rooms over 900 square feet require more than a single sensor Figure 5 Smoke alarm mounting locations Areas with rough ceilings or short transom type walls coming down from the ceiling require additio...

Page 3: ...ut the panel in sensor test mode Although not neces sary for this model it is a good practice to maintain Refer to the specific panel installation instructions for details Simon and Advent panels must be in sensor test If not you will not see anything at the panel WARNING Commander and Caretaker panels will go into alarm if not in sensor test when the test button is pressed 2 Press and hold the te...

Page 4: ...Notify fire department from a neighbor s phone WARNING If you arrive at the premises and hear sirens do not attemp to enter the building Call for emer gency assistance from a neighbor s phone Floor Plan Example Figure 9 is an example of a multilevel floor plan Use it as a guide and draw your floor plan on the next page Figure 9 Example of a floor plan Your Floor Plan When establishing your excape ...

Page 5: ...5 ESL Smoke Sensor Model 562 Emergencies Preliminary ...

Page 6: ... 848 95 Residential Installations UL 268 60 849 95 Commercial Installations This device complies with part 15 of the FCC rules Operation is subject to the following two conditions This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by Interactive Te...

Reviews: