3
SuperBus® 2000 2 x 20 VFD Alphanumeric Touchpad
Wiring
Wiring Panels
UltraGard Panels
1.
Connect the touchpad wiring to the panel terminals as
shown in Figure 3. Wire multiple touchpads in parallel.
2.
If desired, connect an optional hardwire switch to the
yellow touchpad wires as shown in Figure 3 (unsuper-
vised in UltraGard systems).
Note
The optional touchpad hardwire input must be added
to panel memory. See the UltraGard panel
Installation
Instructions or Reference Manual for setting the con-
figuration.
3.
Insert the touchpad wiring harness connector onto the
pins located on the rear of the unit. Make sure the yel-
low wires are to the left.
Figure 3. Wiring the Touchpad to UltraGard Panels
Concord/Concord Express Panels
1.
Connect the touchpad wiring to the panel terminals as
shown in Figure 4. Wire multiple touchpads in parallel.
2.
If desired, connect an optional hardwire switch to the
yellow touchpad wires as shown in Figure 4.
Concord Express Systems- Wire a 2K ohm EOL resis-
tor (49-467) in series with normally closed switches
and in parallel with normally open switches (see
Figure 4).
Concord Systems with software version 2.0 or newer-
Wire a 2K ohm EOL resistor (49-467) in series with
normally closed switches and in parallel with normally
open switches (see Figure 4).
Concord Systems with software versions 1.0–1.6 - This
switch must be unsupervised and a resistor must not be
used.
Note
The optional touchpad hardwire input must be added
to panel memory. See the Concord/Concord Express
panel
Installation Instructions for setting the
configuration.
3.
Insert the touchpad wiring harness connector onto the
pins located on the rear of the unit. Make sure the yel-
low wires are to the left, as shown.
Figure 4. Wiring the Touchpad to Concord and
Concord Express Panels
Advent Panels
1.
Splice the touchpad wiring to the panel SuperBus wir-
ing harness as shown in Figure 5. Wire multiple touch-
pads in parallel.
2.
If desired, connect an optional hardwire switch to the
yellow wires on the touchpad wiring harness. Wire a
2K ohm EOL resistor (49-467) in series with normally
closed switches and in parallel with normally open
switches (see Figure 5).
Note
The optional touchpad hardwire input must be added
to panel memory. See the Advent panel
Installation
Instructions for setting the configuration.
12
13
14
15
GND
DC
OUT
BUS
B
BUS
A
CONTROL PANEL
NOT
USED
OPTIONAL
SWITCH
WITH MAGNET
YELLOW
BLACK
RED
WHITE
GREEN
WIRING HARNESS
49-430
TAB
SLOT (3)
8557148B.DS4
(Not to be used in UL
listed installations)
SHIELDED
CABLE
Connect Shield To Earth Ground
3
4
5
6
GND
+12V
BUS
BUS
B
BUS
A
PANEL TERMINALS
NOT
USED
OPTIONAL
N/C SWITCH
WITH MAGNET
YELLOW
BLACK
RED
WHITE
GREEN
TOUCHPAD
WIRING HARNESS
49-430
TAB
SLOT (3)
8557155B.DSF
OPTIONAL
N/O SWITCH
WITH MAGNET
2K OHM
EOL RESISTOR
(Concord 2.0 or later
and Concord
Express panels)
SHIELDED
CABLE
Connect Shield
to Earth Ground