Technical data
Page 39
4.4
Motor connector [X6]
Table 13:
Technical data: motor connector [X6]
Type
Specifications for operation with 3x 400 VAC [± 10%], 50 Hz
Nominal output power
3.0 kVA
6.0 kVA
Max. output power for 5 s
6.0 kVA
12.0 kVA
Nominal output current
5 A
RMS
10 A
RMS
Max. output current for 5 s
10 A
RMS
(15 A
RMS
for 2 s)
20 A
RMS
Max. output current for 0.5 s *)
20.0 A
RMS
(f
el
≥ 20 Hz)
40.0 A
RMS
(f
el
≥ 20 Hz)
Current derating from
12.5 kHz
5 kHz
Clock frequency
4 … 16 kHz (programmable via the software)
Holding brake 24 V
Signal level depending on the switching state,
high-side/low-side switch / 2 A max.
Motor temperature sensor
Normally closed contact, normally open contact, PTC, KTY
+ 3.3 V/5 mA
Power loss/efficiency (with regard to the
nominal power)**)
Typically 8% / 92%
*) In the case of lower electrical rotational frequencies (f
el
), shorter periods apply to the
; see the
following tables.
**) "As a rating guideline".