Technical data
Page 36
4
Technical data
4.1
General technical data
Table 5:
Technical data: ambient conditions and qualification
Range
Values
Permissible temperature ranges
Storage temperature:
-25°C to +70°C
Operating temperature: 0°C to +40°C
+40°C to +50°C with power reduction 2.5%/K
Permissible installation altitude
Maximum installation altitude 2000 m above MSL; with a power reduction of 1% per
100 m as of 1000 m above MSL
Atmospheric humidity
Relative humidity up to 90%, non-condensing
Type of protection
IP20
Protection class
I
Pollution degree
2
CE conformity
Low voltage directive:
EMC directive:
2006/95/EC, as proved by the application of the harmonised standard EN 61800-5-1
2004/108/EC, as proved by the application of the harmonised standard EN 61800–
3
cULus certification
Listed as per UL 508C, C22.2 No. 274-13
Table 6:
Technical data: dimensions and weight
Type
Dimensions including the
mounting plate (H * W * D)
334.5 mm * 69 mm * 245.5 mm
Housing dimensions
(H * W * D)
250 mm * 69 mm * 240 mm
Weight
approx. 3.7 kg