Function
and Features
Copyright ©ITECH Electronics Co., Ltd.
17
MAX VOLT Set the max output voltage
SYST SET
P-MEN (RESET)
Reset
Power is restored to factory setting
Keep
Set the power-on state as the last power off state
P-OUT (OFF)
OFF
Enable the power-on output state to be off mode
Keep
Set the power-on output state to be the last power-off
output state
COMM (GPIB)
GPIB
ADDR
Address can be set within 0-30
RS232
BAUD
4800
9600
19200
38400
57600
115200
NONE 8BIT
NONE 8BIT
EVEN 8BIT
ODD 8BIT
MODE
SIGNAL
MUX
ADDR.
Address can be set
within 0-30
USB
RS485
BAUD
4800
9600
19200
38400
57600
115200
NONE 8BIT
NONE 8BIT
EVEN 8BIT
ODD 8BIT
MODE
SIGNAL
MUX
ADDR.
Address can be set
within 0-30
BEEP (ON)
OFF
Close the key sound
ON
Open the key sound
KNOB
(ON)
LOCK
Lock the rotary knob function
ON
Unlock the rotary knob function
Ext-C
OFF
Disable external signal control function
ANA
Enable external analog control function
DIGIT
Enable external digital control function
TRIG (MANUAL)
MANU
Local keyboard trigger
BUS
External trigger
MEM (GROUP1)
GRP1-8
Save and recall operation