Error Information
Copyright © Itech Electronic Co., Ltd.
42
Chapter13 Error Information
Error Code List
Error
code
Error information
Example
110
"No input command"
Send empty command.
120
"Parameter
overflowed"
The setting value exceeds the range. For
example, CURRent 100.0
130
"Wrong
units
for
parameter"
For example, CURRent 5.0V, the unit is
wrong.
140
"Wrong
type
of
parameter"
For example, OUTPut:TIMer 100001.0.
150
"Wrong number of
parameter"
For example, CURRent 5.0,6.
160
"Unmatched
quotation mark"
For example, CALibrate:SECure 0,"6831'.
165
"Unmatched bracket"
For example, CURRent (5.
170
"Invalid command"
The command is invalid or the format is
wrong, including the spelling problems.
For example, CUR 5.0.
180
"No entry in list"
The command needs three parameters
while the program only processes two
commands practically.
191
"Too many char"
The sending data length is over 256 while
using serial port or USB.
-200
"Execution error"
The command execution is invalid due to
wrong command status or wrong setting.
For example, sending *TRG command
must be under the BUS trigger method.
If the trigger method is MANUAL, *TRG
command is invalid.
-310
"System error"
Undetermined error code.
-350
"Too many errors"
Too much error in the stack.
-410
"Query
INTERRUPTED"
While using USB communication, no
parameters is returned after sending
query command, the instrument will
prompt an error. Some status or
parameter setting command need to be
followed by a query command i.e. you
need to send the query command after
sending this setting command, if you
send another setting command after
sending this setting command, the
instrument will prompt an error.
-430
"Query
DEADLOCKED"
While using USB communication, if you
send query command when the query
region is full, the instrument will prompt
an error.
0
"No error"
No error.
2
"Mainframe
Initialization Lost"
During the start-up program initialization,
if the instrument can’t read the user
setting
parameters
and
data from
EEPROM, the system will prompt an