background image

                                                               

 

 

 

 

 
 
 

 
 
 
 

Internal Resistance Tester 

 

IT5102

 

Programming Guide 

 

 
 
 
 

 

 

 

 
 
 

 
 
 
 
 
 
 
 

 

                                                                           

                                          Model: IT5102/IT5102E 

                      Version: 1.0 

           
 

Summary of Contents for IT5102 Series

Page 1: ...Internal Resistance Tester IT5102 Programming Guide Model IT5102 IT5102E Version 1 0...

Page 2: ...in this document that conflict with these terms the warranty terms in the separate agreement shall prevail Technology Licenses The hardware and or software described herein are furnished under a lice...

Page 3: ...as all the freights duties and other taxes shall be on the account of customer Limitation of Warranty This Warranty will be rendered invalid if the product is Damaged resulting from customer wired cir...

Page 4: ...s should be capable of bearing maximum short circuit of electronic load without overheating If there are multiple loads each pair of the load power cord must be carry out the full rated short circuit...

Page 5: ...h the WEEE Directive 2002 96 EC marking requirement This affix product label indicates that you must not discard the electrical electronic product in domestic household waste This symbol indicates the...

Page 6: ...2010 EN 55011 2009 A1 2010 Group 1 Class A IEC 61000 4 2 2008 EN 61000 4 2 2009 IEC 61000 4 3 2006 A1 2007 A2 2010 EN 61000 4 3 2006 A1 2008 A2 2010 IEC 61000 4 4 2004 A1 2010 EN 61000 4 4 2004 A1 20...

Page 7: ...rface 9 Chapter2 System Command 10 SYSTem VERSion 10 SYSTem ERRor 10 SYSTem CLEar 11 SYSTem LOCal 11 SYSTem REMote 11 SYSTem RWLock 12 Chapter3 Configuration Commands 13 CHANnel VOLTage GROUp ENABle N...

Page 8: ...e the third keyword Colon is used for separating the command keyword and the next level keyword 1 2 Command Type of SCPI SCPI has two types of commands common and subsystem Common commands generally a...

Page 9: ...different subsystems you need to be able to reset the header path to a null string within a message You do this by beginning the command with a colon which discards any previous header path For exampl...

Page 10: ...ou are reading back a measurement array you must dimension the array according to the number of measurements that you have placed in the measurement buffer Read back all the results of a query before...

Page 11: ...or four letters such as VOLT STAT and DEL Query Indicator Following a header with a question mark turns it into a query VOLTage VOLTage PROTection If a query contains a parameter place the query indic...

Page 12: ...is the message sent by the instrument to the computer in response to a query command Sending a response message After sending a query command the response message is placed in the Output Queue When t...

Page 13: ...ommand strings For example VPP VRMS DBM indicates that you may assign APP VRMS or DBM in the above commands Vertical stripes are not sent along with command strings Angle brackets in the second exampl...

Page 14: ...a command requires several Parameter then a comma must be used to separate adjacent Parameter Space You must use blank characters TAB or Space to separate Parameter with key words of commands Generic...

Page 15: ...ically round the input parameter to acceptable values The following commands require numerical Parameter of frequency value SOURce 1 2 FREQuency CENTer Frequency MINimum MAXimum NR1 represents an inte...

Page 16: ...wing command DISPlay TEXT quoted string For example the following commands display message of WAITING without quotation marks on the front panel of the instrument DISP TEXT WAITING Single quotation ma...

Page 17: ...n ERROR lighted in the front panel when a fault or sevral faults are occurred The maximum 20 items message can be saved in instrument once the command is sent one piece of error message is read 1 Sequ...

Page 18: ...ameters None Example SYST CLE Returned Parameters None Related command CLS SYSTem LOCal This command is used to switch the instrument to local control mode control from panel In this mode all of keys...

Page 19: ...ple SYST REM SYSTem RWLock This command is transmit through RS232 interface the same function as SYSTem REMote but the difference is this command can lock LOCAL button as well When this command is exe...

Page 20: ...e measurement function of the corresponding channel 1 represents the disabling and 0 represents the disabling Command syntax VOLTage GROUp ENABle NR1 NR2 Parameter NR1 Group 0 16 NR2 enable or disable...

Page 21: ...ommand selects channel seting the parameter after select the channel number Command syntax CHANnel SET NRf Parameters 1 136 IT5102E 1 272 IT5102 Example CHAN SET 1 Query Syntax CHANnel SET Return Para...

Page 22: ...nnel 0 disable 1 enable Command syntax CHANnel RESistance STATe bool Parameters 0 1 ON OFF Default Value ON Example CHAN RES 0 Query Syntax CHANnel RESistance STATe Return Parameters Channel number wh...

Page 23: ...Voltage Value Relevant Command CHAN SET CHANnel MEASure RESistance This command is used to query the internal resistance measurement value of present channel Command syntax MEASure RESistance Paramet...

Page 24: ...None CHANnel QUEStionable NUMber This command is used to query the counts of channels Command syntax CHANnel QUEStionable NUMber Parameters None Example CHAN QUES NUM Return Parameters NRf Relevant Co...

Page 25: ...tes low range and 0 indicates high range Command syntax CHANnel VOLTage RANGe STATe bool Parameters 0 1 ON OFF Default Value ON Example VOLT RANG 0 Query Syntax VOLTage RANGe STATe Return Parameters 0...

Page 26: ...tion frequency for measurement 0 indicates 500HZ and 1 indicates 1000HZ Command syntax CHANnel FREQuency STATe bool Parameters 0 1 or ON OFF Default Value ON Example FREQuency 0 Query Syntax FREQuency...

Page 27: ...Syntax PANEl STATe Return Parameters 0 1 Relevant Command PANE CHANnel FILTer STATe This command enbles the filter function or disables the filter function Command syntax CHANnel FILTer STATe bool Par...

Page 28: ...dard event enable register Setting parameter can determine which bit of standard event register is 1 and the byte will enable ESB of status byte register is 1 Command syntax ESE NR1 Parameters 0 255 E...

Page 29: ...meters None Return Parameters AARD Example ITECH IT5102 KN34243232 01 00 RST This command reset the power supply to default settings Command syntax RST Parameters None SRE n This command can set the p...

Page 30: ...ue of bit6 in status byte register will be clean Query Syntax STB Parameters None Return Parameters NR1 Relevant Command CLS ESE ESR WAI This command instructs the internal resistance tester not to pr...

Page 31: ...roducts If you have any doubt about this product please contact us as follow 1 Please refer to the CD ROM of related user s manual in package 2 Visit ITECH website www itechate com 3 Select the most c...

Reviews: