background image

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

When Installing the Unit

    Never  plug  in  nor remove the power  supply  plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

    When unplugging  the  power  supply cord, be sure
    to grasp the  power  supply  plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

    When moving the unit, be sure to remove its power 
    supply cord  from the  wall  outlet.  Moving  the unit
    with the  power  cord  connected  to  the outlet may
    cause damage to the power cord, resulting in fire or 
    electric shock. When  removing the power cord,  be
    sure to hold its plug to pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating  sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

When the Unit is in Use

    Do not place heavy objects on the unit as  this  may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
    Loud noise produced at high volume when power is 
    switched  on  can  impair  hearing.

    Do not operate  the  unit  for an  extended  period of 
    time with  the sound distorting. This  is  an indication
    of  a  malfunction,  which  in  turn  can cause heat to
    generate and result in a fire.

    Contact your 

 dealer as  to the  cleaning. If  dust

    is  allowed  to accumulate  in  the  unit  over  a  long 
    period of  time, a  fire  or  damage  to  the  unit  may 
    result.

ITC

  If dust accumulates on the power supply plug or in
  the  wall  AC  outlet,  a  fire  may  result.  Clean  it 
  periodically. In addition, insert the plug in the wall 
  outlet securely.

  Switch off  the  power, and unplug the power  supply
  plug  from the  AC outlet  for  safety  purposes when 
  cleaning  or  leaving the unit unused for  10  days or 
  more. Doing otherwise  may cause a fire  or  electric 
  shock.

SAFETY PRECAUTIONS

4

Due to product upgrades, while some of the features and specification in the user manual does not 
match the actual functions, sorry for any inconvenience and  thanks for your kind understanding!

Summary of Contents for TS-4500DT

Page 1: ...ions in this manual to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference PUBLIC ADDRESS SYSTEM PUSH ENTER USB TS 4500DT PROFESSIONAL POWE...

Page 2: ...ONS 3 2 GENERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 7 5 OPERATION ILLUSTRATION 8 6 9 7 APPLICATIONS 10 8 BLOCK DIAGRAM 11 9 SPECIFICATIONS 12 10 DI...

Page 3: ...in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electr...

Page 4: ...in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause inju...

Page 5: ...RS1 4 composite input interfaces 6 There are three levels of input sensitivity optional in two channel amplifier which can easily accept wide range signal source input 7 Stereo or bridge operation mod...

Page 6: ...l bridge connection indicator 9 Channel 4 parallel bridge connection indicator 10 USB control port 11 Encoder adjust related parameters of TFT screen short press to enter lock screen state 12 4 inch c...

Page 7: ...CHA CHB channel bridge stereo parallel transfer switch STEREO mode Channels A and B work independently The input signal of channel A is output through A output port And the input signal of channel B...

Page 8: ...his equipment and other external equipment 3 Connect the power line and turn it on Please make sure that the power switch of equipment and its connected equipment are turned off in the OFF position Tu...

Page 9: ...ng 5 Shutdown the system 1 Turning the volume knob to the left until the minimum position 2 Turning off the panel power switch of the professional power amplifier at 0ff In turn shutoff processor equi...

Page 10: ...2 OUTPUT 1 1 2 2 OUTPUT 1 1 2 2 OUTPUT 1 1 2 2 SIG SIG SIG SIG SIG SIG SIG SIG SIG SIG LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL 2 3 4 5 6 7 8 10 0 1 9 2 3 4 5 6 7 8 10 0 1 9...

Page 11: ...WER CLASS D OUTA 4R OUTB 4R Dante DSP TFT INPUT MODULE INPUT 4 OUTPUT 4 12V 5V 12V OUTPUT 4 LIMIT MODULE OUTC 4R OUTD 4R AC POWER AC POWER OUTPUT A B 12V 5V 12V 5V OUTPUT C D POWER CLASS D INPUT A INP...

Page 12: ...HD N at 1 8 power SNR A weighted Damping coefficient 1KHz Resolution 1KHz TS 4500DT 350W 4 500W 4 1000W 2 XLR TRS interface 34 4dB 0 775V 10K unbalanced 20K balanced 20 20KHz 0 2dB 0 05 90dB 200 8 ohm...

Page 13: ...CHB INPUT CHA INPUT INPUTS BRIDGE STEREO PARALLEL CHC INPUT CHD INPUT CHC OUT CHD OUT BRIDGE 8 2 2 PDS NEQ 1 1 BRIDGE STEREO PARALLEL DANTE CHA OUT CHB OUT BRIDGE 2 2 PDS NEQ 1 1 2 2 PDS NEQ 1 1 2 2...

Page 14: ...PUBLIC ADDRESS SYSTEM VersionV0 1...

Reviews: