background image

 SAFETY PRECAUTIONS

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

     Never plug in nor remove the  power supply  plug
     with wet hands, as   doing so  may cause electric
    shock.

     When unplugging   the  power   supply cord, be sure
     to grasp the   power  supply   plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

     When moving the unit, be sure  to remove its power 
     supply cord   from the  wall   outlet.  Moving   the unit
     with the   power  cord   connected  to   the outlet may
     cause damage to the power cord,  resulting in fire or 
     electric shock. When   removing the power cord,  be
     sure to hold its plug to  pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating   sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

     Do not place heavy objects on the unit as this may
    

cause it to fall or break  which may result in personal

 

    

injury and/or property damage. In addition, the object

     itself may fall off and cause injury and/or damage.

    

Make sure that the volume  ontrol is set to minimum 

     position before power is switched on. Loud noise
     produced at high volume when power is switched 
     on can impair hearing.

     Do not operate the unit for an extended period of 
    

time with the sound distorting. This is an indication

     of a malfunction, which in turn can cause heat to
     generate and result in a fire.

     Contact your 

 dealer as to the cleaning. If

     dust is allowed to accumulate in the unit over a 
     long period of time, a fire or damage to the unit 
    may result.

ITC

  If dust accumulates on the power supply plug or in
  the   wall  AC  outlet, a fire may result. Clean it peri-
  

odically. In addition, insert the plug in the wall outlet 

  securely.

  Switch off  the power, and unplug the power supply
  plug from  the AC outlet for  safety purposes  when 
  cleaning or leaving the unit unused for 10  days or 
  more. Doing otherwise may cause a fire  or electric 
  shock.

Due to product upgrades, while some of the 
features and specification in the user manual 
does not match the actual functions, sorry for
any inconvenience and  thanks for your kind 
understanding!

When Installing the Unit

When Installing the Unit

2

Summary of Contents for T-2120D

Page 1: ...is unit We also recommend that you keep this manual handyfor future reference OPERATION MANUAL CLASS D AMPLIFIER T 2120D 2240D 2350D 2500D PUBLIC ADDRESS SYSTEM POWER OFF ON 5 0 1 2 3 4 6 7 8 9 10 5 0...

Page 2: ...Function 5 5 2 Read before using the amplifier 5 5 3 Key operation on the panel 6 5 4 Remote operation 6 5 5 Select the input channel 7 5 6 DC24V backup power battery power supply operation 7 5 7 Fun...

Page 3: ...ke no furtherattempt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object gets int...

Page 4: ...ects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure th...

Page 5: ...igh efficient active APFC power factor correction power switch Wide voltage 190 240V 50 60Hz to adjust to the work scope With DC24V backup battery function Built in high efficient Class D power amplif...

Page 6: ...0 240V 50Hz Power input Cooling fan 4 PROT 5 POWER SWHIT 6 POWER Protection Indicator Up turn on the power Down turn off the power Power Indicator 4 NOMENCLATURE AND FUNCTIONS 4 1 FRONT PANEL 4 2 REAR...

Page 7: ...voltage amplifier a speaker is disconnected and it will not affect the voltage in the entire system line so it will not affect the broadcast in other classes Constant voltage amplifier and speaker con...

Page 8: ...the same time after about 3 seconds the light turns off The amplifier built in protection relay closed power amplifier and the output connection is regular After device enters to the working status i...

Page 9: ...udio source and turn on master volume control knob the indicator is gleaming Turning up the volume the indicator becomes more bright which means the signal output is greater PEAK Orange topping indica...

Page 10: ...se the device please do not directly touch the 100V speaker output interface of the exposed metal parts in the rear panel to avoid electrical shock 100V COM 41 T 2240D 20 T 2500D 28 T 2350D 6 CONNECTI...

Page 11: ...1 1 2 2 OUTPUT 1 1 2 2 OUTPUT 1 1 2 2 SIG SIG SIG SIG SIG SIG SIG SIG SIG SIG LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL 2 3 4 5 6 7 8 10 0 1 9 2 3 4 5 6 7 8 10 0 1 9 2 3 4 5 6...

Page 12: ...8 BLOCK DIAGRAM 10...

Page 13: ...e control and status monitor Signal peak protection and power PROTECTION High temp overload short circuit DIMENSIONS WEIGHT 484X300X44 POWDR CONSUMPTION POWER SUPPLY 190 240V 50 60Hz Specific voltage...

Page 14: ...PUBLIC ADDRESS SYSTEM VersionV0 2...