3. FEATURES

   This range of power amplifiers are designed for general commercial and industrial public address ap-

  plications. Rack mount design in 2U type, rated power ranges from 60W to 240W which provides a 

  wide selection to meet different size sound system needs. Both balanced and unbalanced line inputs

  make it selectable for installer, balanced line output feeds to another power amplifier as well as secu-

  res the signal transmission is less noise and longer distance. 70V, 100V and 4-16ohm speaker outputs

 are convenient for installation  when selection different speaker matching. A master volume control is 

  included.  Complete protection includes clip,  short circuit,  high temp and overload. Indications  for 

 power,signal, clip, protection and temp.

2. GENERAL DESCRIPTION

1.  

Rack mount amplifier in 2U type

2.  Rated power from60W to 240W

3.  70V, 100V and 4~16ohm speaker outputs

4.  solated transformer for human safety operation

5.  Balanced XLR type line input and unbalanced 1/4 inch TRS phone jack line input

6.  Balanced XLR type line output feeds to another power amplifier

7.  Reliable protection of over heat, over load, clip & short circuit.

8.  Indications for power, signal, clip, protection and temp

9.  Excellent device of radiator cooling fanner that ensures working effectively.

10. GND/lift switch to have two options: earth line grounded or lifted

5

Summary of Contents for T-1S120

Page 1: ...o recommend that you keep this manual handyfor future reference PUBLIC ADDRESS SYSTEM ON OFF POWER CLIP TEMP PROT SIGNAL VOLUME 5 0 1 2 3 4 6 7 8 9 10 POWER AMPLIFIER T 1S60 ON OFF POWER CLIP TEMP PRO...

Page 2: ...CONNECTIONS 8 6 OPERATION GUIDANCE 6 1 9 6 2 9 6 3 10 6 4 POWER SUPPLY INPUT 10 6 5 SPEAKER OUTPUTS 4 16 70V 100V 11 7 12 8 APPLICATIONS 13 9 BLOCK DIAGRAM 14 10 SPECIFICATIONS 15 11 DIMENSIONAL DIAGR...

Page 3: ...as doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these te...

Page 4: ...ock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fa...

Page 5: ...ker matching A master volume control is included Complete protection includes clip short circuit high temp and overload Indications for power signal clip protection and temp 2 GENERAL DESCRIPTION 1 Ra...

Page 6: ...ling down 4 PROT The protection indicator will be light on when the constant output is 160 higher than the rated output the output will be cut to protection the amplifier from damage This indicator wi...

Page 7: ...ack 12 LINK OUTPUT 6 35TRS Balanced or unbalanced output music signal unbalanced output use of non equilibrium 6 35TRS jack 13 LINE CASCADE OUTPUT CORLEONE SOCKET XLR output signal of power amplifier...

Page 8: ...5 CONNECTIONS SPEAKER CONNECTIONS 70V 4 16 100V 4 16 LINE 70V COM 70V LINE 41 20 100V LINE T 1S120 T 1S240 83 42 T 1S120 T 1S240 100V 70V 4 16 COM 4 16 100V 70V COM 4 16 8 81 T 1S60 166 T 1S60...

Page 9: ...NE INPUT 70V Speaker Output 6 3mm phono jack 180 3 pole XLR 1 foot for the ground 2 feet Signal Hot side positive 3 feet signal cold side negative 1 2 3 1 CH Pre Amplifier 100V 70V 50V 4 COM LINK XLR...

Page 10: ...The line output could link another amplifier for more loudspeaker connection The line output volume level is controlled by front panel knobs Notice please minimum the volume knob to MIN position when...

Page 11: ...s High impedance speaker output only for high impedance speaker connection and low impedance speaker output only for low impedance speaker connection Speaker total power output shall be no higher than...

Page 12: ...output if the LED is not ligh ting please check the input circuit When you start the machine it will run into auto checking condition its protection LED yellow will shine 3 seconds If the protection...

Page 13: ...MC INPUT MIC2 MIC3 LINE INPUT OUTPUT COM 4 16 70V 100V REC LINE 10 LINE 9 LINE 8 LINE 7 LE FT RIG HT MIC INPUTS MIC LINE INPUTS 220V 50Hz MAX 9 9W P T T 1 2 3 4 5 6 7 8 9 10 INSIDE AC DC FUSE 220VAC D...

Page 14: ...9 BLOCK DIAGRAM EB PA 100V 70V CH1 LINK CH1 INPUTS TO 4 16 COM POWER Z 220 240V 50 60Hz PT 14...

Page 15: ...3 rated power Power switch volume control Power clipping Signal protect and high AC fuse short circuit clipping and high temperature DIMENSION mm NET WEIGHT GROSS WEIGHT 484X353X88 POWER CONSUMPTION...

Page 16: ...Over Over 100 94 11 DIMENSIONAL DIAGRAM 84 84 323 317 88 436 100 Over 6 25 484 UNIT mm UNIT mm 16 GND LIFT INPUTS LINK COM 4 16 70V 100V OUTPUTS COM COM INPUTS LINK 1 1 2 2 3 3 XLR BAL 1 GND 2 HOT 3 C...

Page 17: ...PUBLIC ADDRESS SYSTEM PUBLIC ADDRESS SYSTEM VersionV0 4...