background image

GND

LIFT

INPUTS

LINK

COM  4-16

70V   100V

OUTPUTS

COM  

COM  

INPUTS

LINK

1

1

2

2

3

3

XLR BAL
1-GND
2-HOT+
3-COLD-

6.5 

 

SPEAKER OUTPUTS 4~16

& 70V& 100V

  

4-16

,SPEAK

70V,SPEAK

100V,SPEAK

+

-

+

-

+

-

USE ONLY WITHA 250VFUSE

OUTPUTS

COM  4-16    70V   100V

COM   COM  

GND

LIFT

C

USE ONLY WITHA 250VFUSE

OUTPUTS

COM  4-16    70V   100V

COM   COM  

GND

LIFT

C

USE ONLY WITHA 250VFUSE

OUTPUTS

COM  4-16    70V   100V

COM   COM  

GND

LIFT

C

 

High impedance and low impedance both speaker output  for different application use. Only choose one of the

positive end from 4~16

& 70V& 100V, then connect the negative end"COM" and one the positive end to the

speaker's according ends. High impedance speaker output only for high impedance speaker connection and

low impedance speaker output only for low impedance  speaker connection. Speaker total power output shall

be no higher than 80% percent of the  amplifier rated power output.

  

Notice:
No mixing connected the positive and negative ends between the amplifier and loudspeaker.
Never allowed to use more than one output among 4~16

/70V/100V.

Speaker continuous power output never higher than 80% of the amplifier rated power output.
Never connect high impedance output to low impedance speaker nor connect low impedance output to
 high impedance speaker.
Please cover the speaker output ends after wiring to avoid any touch. The speaker output are high 
voltage, never touch by human body to avoid electricity shock.

          
       

11

Picture 1.5

OPERATION GUIDANCE

Summary of Contents for T-1S120

Page 1: ...o recommend that you keep this manual handyfor future reference PUBLIC ADDRESS SYSTEM ON OFF POWER CLIP TEMP PROT SIGNAL VOLUME 5 0 1 2 3 4 6 7 8 9 10 POWER AMPLIFIER T 1S60 ON OFF POWER CLIP TEMP PRO...

Page 2: ...CONNECTIONS 8 6 OPERATION GUIDANCE 6 1 9 6 2 9 6 3 10 6 4 POWER SUPPLY INPUT 10 6 5 SPEAKER OUTPUTS 4 16 70V 100V 11 7 12 8 APPLICATIONS 13 9 BLOCK DIAGRAM 14 10 SPECIFICATIONS 15 11 DIMENSIONAL DIAGR...

Page 3: ...as doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these te...

Page 4: ...ock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fa...

Page 5: ...ker matching A master volume control is included Complete protection includes clip short circuit high temp and overload Indications for power signal clip protection and temp 2 GENERAL DESCRIPTION 1 Ra...

Page 6: ...ling down 4 PROT The protection indicator will be light on when the constant output is 160 higher than the rated output the output will be cut to protection the amplifier from damage This indicator wi...

Page 7: ...ack 12 LINK OUTPUT 6 35TRS Balanced or unbalanced output music signal unbalanced output use of non equilibrium 6 35TRS jack 13 LINE CASCADE OUTPUT CORLEONE SOCKET XLR output signal of power amplifier...

Page 8: ...5 CONNECTIONS SPEAKER CONNECTIONS 70V 4 16 100V 4 16 LINE 70V COM 70V LINE 41 20 100V LINE T 1S120 T 1S240 83 42 T 1S120 T 1S240 100V 70V 4 16 COM 4 16 100V 70V COM 4 16 8 81 T 1S60 166 T 1S60...

Page 9: ...NE INPUT 70V Speaker Output 6 3mm phono jack 180 3 pole XLR 1 foot for the ground 2 feet Signal Hot side positive 3 feet signal cold side negative 1 2 3 1 CH Pre Amplifier 100V 70V 50V 4 COM LINK XLR...

Page 10: ...The line output could link another amplifier for more loudspeaker connection The line output volume level is controlled by front panel knobs Notice please minimum the volume knob to MIN position when...

Page 11: ...s High impedance speaker output only for high impedance speaker connection and low impedance speaker output only for low impedance speaker connection Speaker total power output shall be no higher than...

Page 12: ...output if the LED is not ligh ting please check the input circuit When you start the machine it will run into auto checking condition its protection LED yellow will shine 3 seconds If the protection...

Page 13: ...MC INPUT MIC2 MIC3 LINE INPUT OUTPUT COM 4 16 70V 100V REC LINE 10 LINE 9 LINE 8 LINE 7 LE FT RIG HT MIC INPUTS MIC LINE INPUTS 220V 50Hz MAX 9 9W P T T 1 2 3 4 5 6 7 8 9 10 INSIDE AC DC FUSE 220VAC D...

Page 14: ...9 BLOCK DIAGRAM EB PA 100V 70V CH1 LINK CH1 INPUTS TO 4 16 COM POWER Z 220 240V 50 60Hz PT 14...

Page 15: ...3 rated power Power switch volume control Power clipping Signal protect and high AC fuse short circuit clipping and high temperature DIMENSION mm NET WEIGHT GROSS WEIGHT 484X353X88 POWER CONSUMPTION...

Page 16: ...Over Over 100 94 11 DIMENSIONAL DIAGRAM 84 84 323 317 88 436 100 Over 6 25 484 UNIT mm UNIT mm 16 GND LIFT INPUTS LINK COM 4 16 70V 100V OUTPUTS COM COM INPUTS LINK 1 1 2 2 3 3 XLR BAL 1 GND 2 HOT 3 C...

Page 17: ...PUBLIC ADDRESS SYSTEM PUBLIC ADDRESS SYSTEM VersionV0 4...

Reviews: