10
Min.
Max.
BLOCK
Oil list:
CEPSA SAE80W90
REPSOL EP 80W/90
SHELL SPIRLAXHD OIL 80W/90
ESSO GEAR OIL 80W/90
AGIP ROTRA MP 80W-90
MOBILUDE HD 80W-90
BP ENERGEAR HT 80W-90
CATROL HYPOYC
GULF GEAR MP SAE 80W 90
ELF TRANSGEAR HD 80W-90
Pull out the oil cap for transport , fill the pump with the SAE oil 80W90 being
supplied (or similar oil), up to the level shown on the screen and put on the
working cap (black with a hole).
Approximate oil contents
3
650 cm
ELECTRICAL CONNECTION
The electric protection of the motor must be installed and adjusted
following its nominal instensity (overloaded switch disjuntor). (See
wiring).
A disconnection dispositive must be installed in case of emergency.
The equipment must be protected to avoid untimely sudden starts.
11
ON
OFF
MOLDED CASE CIRCUIT BREAKER
(MCCB)
U
V
W
V1
W1
U1
230 V
400 V
V1
W1
U1
3,4 Amp
2 Amp
ON
OFF
L
N
THREE-PHASE CONNECTION (50/60 Hz)
To work at 230 V we will plug the motor in triangle. Installing a protection.
To work at 400 V it will be a star connection. Installing a protection.
SINGLE PHASE CONNECTION
To work at 230 V single-phase at 50 Hz we will connect directly the motor wire to
the adequate protection. To work at 60 Hz we will connect the connection box
plates as shown in the drawing.
MOLDED CASE CIRCUIT BREAKER
(MCCB)
230 VAC (50 Hz)
N
L
5,3 Amp.
W1
V1
U2
V2
W2
U1