15
Installation
5 OPERATION
The electric motor transmits power via a reducer, consisting of a pinion (A) and an eccentric crown (B)
that drives a connecting cam (C) onto which the diaphragm (D) is screwed. Spring (F) is compressed
during the suction cycle, thus storing energy which is released during the discharge cycle.
By varying the speed of the motor and depending on the operating mode selected in the Control Unit, the
equipment will regulate the flow to the desired value with a maximum variation of 1:3000.
SYSTEM DESCRIPTION
LCD screen
Keyboard
Exit without confirming /
Validate/Run/Stop
Increase/decrease value
Scroll left
Scroll right/test
ESC
ENT
Inputs/outputs
Control
unit
B
A
C
D
F
Injection
valve
Suction valve
Head
Box
Bleed valve
Summary of Contents for DOSmart AC
Page 1: ...ENGLISH ...
Page 46: ......