5.  POWER SOCKET

     Output power socket strips

6.  CORTROL OUT

     

Short signal input

7.  CORTROL OUT

     

Short signal enlarge output

     

     

     

    

8.  ~220-240V 50/60Hz POWER INPUT  
9.  FUSE
10.ALARM OUT
     

Fire control signal output

11.ALARM IN
     

Fire control signal input

     
       
    

     

     

    

4.2   REAR  PANEL

5

8

7

5

3

10

11

12

13

14

15

16

8

6

4

2

1

9

ALARM  IN

ALARM OUT

CORTROL  OUT

A

B

6

7

11 10

9

Summary of Contents for T-6216

Page 1: ...m resultsfrom this unit We also recommend that you keep this manual handyfor future reference POWER SEQUENCER OPERATION MANUAL AUDIO AUDIO PUBLIC ADDRESS SYSTEM T 6216 POWER T 6216 POWER SEQUENCER POWER SEQUENCE 3 4 5 6 7 8 1 2 OFF ON START STOP START KEY STATE SWITCH ...

Page 2: ...ENTS 2 1 SAFETY PRECAUTIONS 3 2 GENERAL DESCRIPTION 5 3 FEATURES 5 4 NOMENCLATURE AND FUNCTIONS 4 1 Front Panel 6 4 2 Rear Panel 7 5 8 6 APPLICATIONS 9 7 SPECIFICATIONS 10 8 DIMENSIONAL DIAGRAM 11 MACHINE OPERATION ...

Page 3: ...t in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unstab...

Page 4: ...g sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to minimum position before power is switched o...

Page 5: ...ss solution from small to big places such us mosques schools hotels and factories to train stadium and air stations 2 GENERAL DESCRIPTION 1 Power up power down sequence for 16 channels 2 It can be connected with timer and intellective controller to achieve automatic control 3 Total capacity of 10KVA ...

Page 6: ...ONS 2 4 1 FRONT PANEL 1 POWER Power indicator 2 START KEY Electronic lock power switch 3 STATE SWITCH 4 POWER SEQUENCE Power output LED indicator 1 4 3 POWER POWER SEQUENCE 3 4 5 6 7 8 1 2 OFF ON START KEY STATE SWITCH START STOP ...

Page 7: ...UT Short signal input 7 CORTROL OUT Short signal enlarge output 8 220 240V 50 60Hz POWER INPUT 9 FUSE 10 ALARM OUT Fire control signal output 11 ALARM IN Fire control signal input 4 2 REAR PANEL 5 8 7 5 3 10 11 12 13 14 15 16 8 6 4 2 1 9 ALARM IN ALARM OUT CORTROL OUT A B 6 7 11 10 9 ...

Page 8: ... electronic lock put to ON ubiety 3 Locating power put to MAJOR ubiety auto matric put through power A each power put through phase difference 1 second time 4 Locating power put to NEXT ubiety aux at discretion put through output power socket strips ...

Page 9: ...3 5A CH4 5A CH6 5A CH5 5A CF CARD COM1 COM2 EM IN EM OUT TM OUT 7 5 3 10 11 12 13 14 15 16 8 6 4 2 1 9 ALARM IN ALARM OUT CORTROL OUT A B MATRIX CONTROLLER 16 CHANNEL POWER SEQUENCER MIXER AMPLIFIER MIXER AMPLIFIER AUX2 OUT AUX1 MIC2 MIC3 MUTE EMC INPUT MIC2 MIC3 LINE INPUT OUTPUT COM 4 16 70V 100V AUX2 OUT AUX1 MIC2 MIC3 MUTE EMC INPUT MIC2 MIC3 LINE INPUT OUTPUT COM 4 16 70V 100V DC24V INPUT SHO...

Page 10: ...216 INDICATORS POWER REQUIREMENTS DIMENSIONS MM CONTROL PROTECTION POWER CONSUMPTION NET WEIGHT 484X368X88 220 240V 50 60Hz START KEY AC fuse 1A 50W 7 2Kg Power LED Power sequencer indicator 5 8Kg GROSS WEIGHT POWER SEQUENCER 10 ...

Page 11: ...Y STATE SWITCH START STOP 8 DIMENSIONAL DIAGRAM 100 Over 100 Over Over 100 UNIT mm 84 88 94 436 484 UNIT mm 6 84 25 328 322 11 7 5 3 10 11 12 13 14 15 16 8 6 4 2 1 9 ALARM IN ALARM OUT CORTROL OUT A B POWER POWER SEQUENCE 1 2 OFF ON START KEY STATE SWITCH START STOP ...

Page 12: ...AUDIO AUDIO PUBLIC ADDRESS SYSTEM VersionV0 1 ...