Italkero PS40 R2 Instruction Booklet Download Page 8

On request, the following accessories are available:

8

GENERAL

MODEL

II 

2H3+

mbar

-

kW

kW

%

-

V~Hz

W

-

n

°

Ø mm

mbar

m

3

/h

kg/h

kg/h

m

3

m

3

/h

kg

1

230 ~ 50

135

IP20

3

20

C13 / C33 / C53 / C63

80

G20

G30/G31

7,4 / 5,07

8 / 5,6

92,5 / 90,7

196

335

39,5

12

28,5/35,8

1,42

0,82

60

G20

G30/G31

5,85 / 4,0

6,5 / 4,55

90,2 / 88,4

155

265

32

12

28,8/36,7

1,30

0,74

40

G20

G30/G31

3,5 / 2,4

3,85 / 2,7

90,5 / 88,5

95

160

23,5

12

28,8/36,8

1,02

0,58

90

G20

G30/G31

9,1 / 6,2

10 / 7,0

91 / 83

245

410

47,5

10

27,2/34,5

1,65

0,95

0,407

0,285

0,688

0,481

0,847

0,593

1,06

0,742

0,303

0,212

0,512

0,358

0,630

0,441

0,788

0,552

G20

0,299

0,209

0,505

0,354

0,621

0,435

0,777

0,544

G30

G31

Fuel

Mains gas supply pressure (nominal) G20

Category of appliance

Type of appliance

Nom. heat output / min. HI

Nom. heat input  /min. HI

Working efficiency  Pn

Efficiency class*

Power supply

NOM power input

Insulation standard

Nozzles

Pressure at nozzles

Gas consumption (15

°

C) nom. / red

.

Quantity of heated air (approximate figure)

Gross weight (with packaging)

* Efficiency class obtained according to prEN 1266 dated 6/1997.

MAX volume, room heated by a

 convector (approximate figure)

Wall spacer bracket 30

DESCRIPTION

CODE

Wall spacer bracket 50

90

°

 curves _Ø 32mm pipe union

Extension Ø 32mm L = 500mm

Extension Ø 32mm L = 1000mm

Outer protection grille "GP" for separate end piece Ø 32mm

Griglia prot. esterna "GPu" per Term. Unico Ø 32mm

Stack for pipe Ø 32mm

90

°

 curve _Ø 54mm pipe union

Extension Ø 54mm L = 500mm

Extension Ø 54mm L = 1000mm

90

°

__curve Ø 54mm cast

Outer protection grille "GP" for separate end piece Ø 54mm

Recessed screen "SDP" for separate end piece Ø 54mm

Stack for pipe Ø 54mm

Weekly TIMER

Wall spacer bracket 70

Wall spacer bracket 90

Daily TIMER  

INSULATION for pipe Ø 54mm L = 1000mm (pack of 4 pcs.)

INSULATION for pipe Ø 32mm L = 1000mm (pack of 5 pcs.)

Inlet/Outlet end piece Ø 54mm L = 6 cm

Inlet/Outlet end piece Ø 32mm L = 5 cm

135

°

 curves _Ø 54mm

135

°

 curves _Ø 32mm

Recessed screen "SDP" for separate end piece Ø 32mm

Outer protection grille "GPu" for combined end piece Ø 54mm

7 0 0 0 0 6 6 6   0 0

7 0 0 0 0 6 7 6   0 0

7 0 0 0 0 7 0 0   0 0

7 0 0 0 0 7 2 0   0 0

7 0 0 0 0 7 1 0   0 0

7 0 0 0 0 3 5 0   0 0

7 0 0 0 0 6 0 0   0 0

7 0 0 0 0 7 3 0   0 0

7 0 0 0 0 3 7 0   0 0

7 0 0 0 0 3 9 0   0 0

7 0 0 0 0 3 8 0   0 0

7 0 0 0 0 7 5 5   0 0

7 0 0 0 0 3 5 0   0 0

7 0 0 0 0 3 6 5   0 0

7 0 0 0 0 7 4 0   0 0

7 0 0 0 0 2 8 0   0 0

7 0 0 0 0 6 8 6   0 0

7 0 0 0 0 6 9 6   0 0

7 0 0 0 0 2 7 0   0 0

7 0 0 0 0 8 5 0   0 0

7 0 0 0 0 8 4 0

7 0 0 0 0 4 6 5   0 0

7 0 0 0 0 4 6 6

7 0 0 0 0 3 7 5   0 0

7 0 0 0 0 7 0 5   0 0

7 0 0 0 0 3 6 5   0 0

7 0 0 0 0 6 1 0   0 0

TECHNICAL SPECIFICATIONS

ACCESSORIES

Summary of Contents for PS40 R2

Page 1: ...Ceiling gas radiators 0694 n BL3197 FORCED PS40R2 PS60R2 PS80R2 PS90R2 PS40R2 PS60R2 PS80R2 PS90R2 INSTRUCTION BOOKLET INSTALLATION AND AFTER SALES SERVICE...

Page 2: ...EEC Electromagnetic Compatibility Directive 89 336 EEC Low Voltage Directive 73 23 EEC 0694 0694 RANGE P o s t e r 4 0 P o s t e r 6 0 P S 4 0 R 2 M 0 0 0 0 P S 6 0 R 2 M 0 0 0 0 P o s t e r 7 0 P S 8...

Page 3: ...nd providing you with all the information we consider necessary for correct and easy installation Thank you once again The Manufacturer 3 GARANZIA The radiator comes with a specified warranty from the...

Page 4: ...tack 26 Checking Pressure Loss Pa 26 Power connections 28 Gas supply connections 29 TECHNICAL AFTER SALES SERVICE Preliminary operations before initial startup 30 Initial startup 30 Control unit malfu...

Page 5: ...any discrepancies contact the Agency that sold the appliance The appliance must be installed by companies approved pursuant to Law no 46 dated 5 March 1990 Upon completing the installation such compa...

Page 6: ...de and restoring normal operation after a fault The remote control permits programming weekly operating periods setting the temperature and star ting summer ventilation 6 GENERAL TERMOCONVETTORE TERMO...

Page 7: ...ol 6 Main switch 7a Integrated room heat probe 7b Split room heat probe 8 Display 9 Battery holder buffer batteries 10 Condenser mod 70 and 90 11 Convection fan 12 Power plug 13 Gas valve 14 Combustio...

Page 8: ...ves _ 32mm pipe union Extension 32mm L 500mm Extension 32mm L 1000mm Outer protection grille GP for separate end piece 32mm Griglia prot esterna GPu per T erm Unico 32mm Stack for pipe 32mm 90 curve _...

Page 9: ...ECTRODE ER DETECTION ELECTRODE EV1 ELECTRIC GAS VALVE F FUSE CL LINE CONNECTOR EV2 POWER MODULATOR L PHASE LINE N NEUTRAL LINE CRD DIGITAL REMOTE CONTROL PS PRESSURE SWITCH TL LIMIT THERMOSTAT SA I IN...

Page 10: ...enu line d Press SELECT key key 5 note keys 1 2 4 and 5 acquire different functions in the different menus required setting e Press keys 1 and 2 to set the required parameter f Press key 4 to store th...

Reviews: