GENERAL

1

Safety thermostat

2

Technical plate Gas Valve

3

Control unit

4

Protection fuse

5

Digital remote control

6

Main switch

7a

"Integrated" room heat probe

7b

"Split" room heat probe

8

Display

9

Battery holder (buffer batteries)

10

Condenser (mod. 70 and 90)

11

Convection fan

12

Power plug

13

Gas valve

14

Combustion fan

15

Room thermostat

16

Burner unit

17

Heat exchanger

16

14

15

13

3

4

5

6

1

2

7b

8

9

10

11

17

12

7a

STRUCTURE

Summary of Contents for PS40 R2

Page 1: ...Ceiling gas radiators 0694 n BL3197 FORCED PS40R2 PS60R2 PS80R2 PS90R2 PS40R2 PS60R2 PS80R2 PS90R2 INSTRUCTION BOOKLET INSTALLATION AND AFTER SALES SERVICE...

Page 2: ...EEC Electromagnetic Compatibility Directive 89 336 EEC Low Voltage Directive 73 23 EEC 0694 0694 RANGE P o s t e r 4 0 P o s t e r 6 0 P S 4 0 R 2 M 0 0 0 0 P S 6 0 R 2 M 0 0 0 0 P o s t e r 7 0 P S 8...

Page 3: ...nd providing you with all the information we consider necessary for correct and easy installation Thank you once again The Manufacturer 3 GARANZIA The radiator comes with a specified warranty from the...

Page 4: ...tack 26 Checking Pressure Loss Pa 26 Power connections 28 Gas supply connections 29 TECHNICAL AFTER SALES SERVICE Preliminary operations before initial startup 30 Initial startup 30 Control unit malfu...

Page 5: ...any discrepancies contact the Agency that sold the appliance The appliance must be installed by companies approved pursuant to Law no 46 dated 5 March 1990 Upon completing the installation such compa...

Page 6: ...de and restoring normal operation after a fault The remote control permits programming weekly operating periods setting the temperature and star ting summer ventilation 6 GENERAL TERMOCONVETTORE TERMO...

Page 7: ...ol 6 Main switch 7a Integrated room heat probe 7b Split room heat probe 8 Display 9 Battery holder buffer batteries 10 Condenser mod 70 and 90 11 Convection fan 12 Power plug 13 Gas valve 14 Combustio...

Page 8: ...ves _ 32mm pipe union Extension 32mm L 500mm Extension 32mm L 1000mm Outer protection grille GP for separate end piece 32mm Griglia prot esterna GPu per T erm Unico 32mm Stack for pipe 32mm 90 curve _...

Page 9: ...ECTRODE ER DETECTION ELECTRODE EV1 ELECTRIC GAS VALVE F FUSE CL LINE CONNECTOR EV2 POWER MODULATOR L PHASE LINE N NEUTRAL LINE CRD DIGITAL REMOTE CONTROL PS PRESSURE SWITCH TL LIMIT THERMOSTAT SA I IN...

Page 10: ...enu line d Press SELECT key key 5 note keys 1 2 4 and 5 acquire different functions in the different menus required setting e Press keys 1 and 2 to set the required parameter f Press key 4 to store th...

Reviews: