background image

14

user

SETTING THE ClOCK ANd 

TImER

 (if present)

First set the time, and then the periods during 
which the heater will be on and off.

• To set the local time:
Turn the clock dial (clockwise only) until 
the local time matches the indicator on the 
control panel.

• To set the heater's operating times (ON):
Gently move up (model SV-SE) the segments 
corresponding to the time periods in which 
you wish the heater to heat the room.

• To set the heater's stop times (OFF):
Gently  move  down  (model  SV-SE)  the 
segments corresponding to the time periods 
in which you wish the heater to stay off.

The heater can be stopped with the function 

selector (set to 0) or with the master switch 

on the control panel.

In the first case, the clock continues running; 

in the second case the clock stops and you 

must set the local time again when you turn 

the appliance back on.

Note, model SV: when the appliance is 

switched off by the timer, the main burner 

goes out, but the pilot light stays on

Summary of Contents for ECO SC

Page 1: ...SC SV SE...

Page 2: ...5 General information 6 Getting to know your convection heater 8 Using the convection heater commissioning 10 setting the clock and timer 14 setting the room thermostat 15 Prolonged disuse 16 Cleanin...

Page 3: ...rom your appliance please have it regularly serviced and repaired with the manufacturer s original spare parts by an Authorised Technical Service Centre You can also stipulate a Scheduled Service Cont...

Page 4: ...r ratify the WARRANTY furnished with the appliance we suggest you read the certificate carefully The Technical Service Centre will give you good advice on how to get the most from your convection heat...

Page 5: ...Should you do so ventilate the room by opening the doors and windows close the fuel gas supply cock contact Technical Service or a qualified technician immediately Do not touch the convection heater w...

Page 6: ...to persons or animals resulting from incorrect installation adjustments or improper use of the appliance The convection heater must be installed by a technician qualified pursuant to Italian Law 5 Ma...

Page 7: ...7 user Gas convection heater type C sealed chamber for heating eco SC eco SV eco SE...

Page 8: ...els a very quiet tangential fan which quickly heats the room to the required temperature SC convection heaters do not have a fan SV heaters have a fan which is actuated by a switch regardless of the p...

Page 9: ...only the clock still runs 5 Room thermostat knob 6 Tangential fan On Off 1 Room thermostat knob 2 Timer 24 h 3 Timer function selector clock timer mode programmable hand room thermostat controlled ope...

Page 10: ...being away for a period of time or after prolonged disuse In such cases proceed as follows Check that the gas cock is open Set the master switch if present to ON or fit the power socket into the appli...

Page 11: ...and check that the burner ignites Turn the thermostat knob to your preferred setting 1 MIN and 7 MAX The burner will stay on changing its power automatically until it reaches the temperature setting a...

Page 12: ...rature the operating led on the control panel will go out In case of malfunction the appliance will go into SHUTDOWN and the red reset led will turn on To reset the appliance press the RESET button an...

Page 13: ...ce the heater is running set the clock to the local time and the timer for automatic operation see the timer instructions To run the heater in automatic mode simply set the function selector if presen...

Page 14: ...h you wish the heater to heat the room To set the heater s stop times OFF Gently move down model SV SE the segments corresponding to the time periods in which you wish the heater to stay off The heate...

Page 15: ...the new setting is done wait for the heater to complete a cycle and check whether you have achieved the desired temperature comfort in the room Repeat until you are satisfied Set the fan switch if pre...

Page 16: ...mpleted SC SV Set the ignition command knob to 0 if present SE Set the function selector to 0 if present SC SV Set the fan switch if present to OFF 0 SE Press the master switch on the control panel le...

Page 17: ...ach areas Donotusesolventsorabrasivedetergents to clean the plastic or painted surfaces use neutral detergents to do so Do not grease synthetic parts To clean the jacket use a soft cloth and a neutral...

Page 18: ...hree attempts set the master switch to OFF and contact Technical Service Eco SE No electrical power If the power led does not turn on when you press the fan switch check that the appliance s plug is p...

Page 19: ...19 user notes...

Page 20: ...3520010101 Rev 0...

Reviews: