background image

Accessories

Active Probes

The functionality can be extended through the use of Active Probes.

Ordering Code

Description

IC57163

Infineon DAP/DAPE Active Probe

IC57166

Infineon USB-C Active Probe

IC57164

Infineon AGBT Active Probe

IC57125-1

ARM HSSTP II Active Probe

IC57150

MPC5x/SPC5x Aurora Active Probe

Power supplies and cables

Ensure proper operation by using approved iSYSTEM power supplies and cables.

Ordering Code

Description

IC30000-PS

19V Power Supply

IC30000-PS-CAR12V

12V Car Power Supply

BB-PSC-EU

Power Supply Cord - EU Plug (type F Plug)

BB-PSC-US

Power Supply Cord - USA Plug (type B Plug)

BB-PSC-IN

Power Supply Cord - India Plug (type D Plug)

BB-PSC-CN

Power Supply Cord - China Plug (type I Plug)

IC50020-10

10 cm 40-pin Ribbon Cable 

IC50020-25

25 cm 40-pin Ribbon Cable

IC50020-40

40 cm 40-pin Ribbon Cable

IC50020-60

60 cm 40-pin Ribbon Cable

IC50020-100

100 cm 40-pin Ribbon Cable

IC50020-150

150 cm 40-pin Ribbon Cable

BB-USB20-180

1.8 m USB 2.0  Cable

BB-USB30-180

1.8 m USB 3.0 Cable

BB-ETHCAT5-100

1 m Cat 5 Ethernet Cable

BB-ETHCAT5-200

2 m Cat 5 Ethernet Cable

BB-WIRE

Grounding Wire

Summary of Contents for iC5700 CI BlueBox

Page 1: ...iC5700 CI BlueBox On Chip Analyzer User Manual V1 0 ...

Page 2: ...ll rights are reserved Duplication of these documents is allowed for personal use In all other cases written consent from iSYSTEM is required iSYSTEM AG All rights reserved All trademarks are property of their respective owners iSYSTEM is an ISO 9001 certified company www isystem com ...

Page 3: ...I BlueBox Important safety notice 5 Package content 6 Specifications 7 Operation 8 Device description 9 Connecting the iC5700 CI to the Target 11 Accessories 14 Declarations 16 User Notes 17 User Notes 18 User Notes 19 ...

Page 4: ...EA IDE Integrated Software Development Environment delivers the visual insights required to debug the embedded application performs timing analysis measures code coverage visualizes RTOS task states and much more More information isystem com winideaide testIDEA The testIDEA environment simplifies the development of unit tests for embedded applications More information isystem com testidea isystem ...

Page 5: ...o avoid potential damage caused by any voltage difference between the device and the target system Use proper overvoltage protection Please ensure proper protection to avoid exposing the BlueBox device or the operator to overvoltage surges e g caused by thunderstorm mains power Do not operate without cover Do not operate the device with cover removed Avoid circuit and wire exposure Do not touch ex...

Page 6: ...omponents iC5700 CI with DTM 25 cm 40 pin ribbon cable Power supply Ordering code IC57000 CI Ordering code IC50020 25 Ordering code IC30000 PS USB 3 0 cable Ethernet cable Grounding wire Ordering code BB USB30 180 Ordering code BB ETHCAT5 200 Ordering code BB WIRE User Manual ...

Page 7: ...CTRICAL Debug signal valid input voltage range 1 8V to 5 5V DC Debug signals 47 Ohm series termination protection resistors ESD protection devices 100mA resettable fuses All inputs except the TDO 10 kOhm pull up resistor TDO input 10 kOhm pull down resistor TMS and TDI debug signals 10 kOhm pull up resistor RESET 1k Ohm pull up resistor buffer driven to prevent current flow into an unpowered iC570...

Page 8: ...Operation Device overview ...

Page 9: ...atures C The grounding socket marked GND should be used together with the supplied Grounding Wire to create an electrical connection between the iC5700 and the target circuitry The socket is suitable for a 2 mm Multi Contact Plug also known as a Banana Plug if building a longer or a replacement cable on your own D The FNet Port provides an interface for the iSYSTEM s range of IOM6 accessories See ...

Page 10: ... connects to first When powering on the system switch the BlueBox unit on before powering on the Target When powering down the system power off the Target before powering off the BlueBox unit FBridge port is not Ethernet port Use only original iSYSTEM accessories for powering and connecting with the BlueBox unit Consult with iSYSTEM before attempting to use any other accessory ...

Page 11: ...BlueBox hardware to work also with a 12V or 24V vehicle battery The necessary power supply Part No IC30000 PS is delivered with the BlueBox unit The power supply comes with the EU type F power plug USA type B power plug India type D power plug or China type I power plug power cord depending on the delivery address Refer to the Accessories chapter for a spare power cord when required An optional 12...

Page 12: ...in and one 40 pin with a permanently fitted to the debug adapter 1 Connect the 40 pin ribbon cable connector to the DTM 1 socket The ribbon cable must always be guided towards the BlueBox front panel with the red wire on the side of the 1 marking optional 2 Align the orientation key of the cable connector with the notch on the BlueBox s 40 pin socket the wider of the two sockets Carefully press th...

Page 13: ...your needs iSYSTEM offers a range of alternative lengths Please refer to the Accessories chapter for available ribbon cables Note that the quality of electrical signals degrades with prolonging the cable iSYSTEM gives no assurance for BlueBox operation with such cable The cable is meant to be used only for boundary cases where BlueBox cannot be connected to the target hardware through the standard...

Page 14: ...V Power Supply IC30000 PS CAR12V 12V Car Power Supply BB PSC EU Power Supply Cord EU Plug type F Plug BB PSC US Power Supply Cord USA Plug type B Plug BB PSC IN Power Supply Cord India Plug type D Plug BB PSC CN Power Supply Cord China Plug type I Plug IC50020 10 10 cm 40 pin Ribbon Cable IC50020 25 25 cm 40 pin Ribbon Cable IC50020 40 40 cm 40 pin Ribbon Cable IC50020 60 60 cm 40 pin Ribbon Cable...

Page 15: ...50152 12 38 pin Mictor MPC5xxx Nexus 16 bit Debug Adapter IC50156 50 pin ERF8 MPC5xxx Nexus 16 bit Debug Adapter IC50160 16 pin 2 54mm Infineon JTAG Debug Adapter IC50160 ECU14 10 pin 1 27mm TriCore ECU14 Debug Adapter IC50160 MEDC17 10 pin 1 27mm TriCore MEDC17 Debug Adapter IC50162 6 pin 2 54mm Infineon I2C Debug Adapter IC50163 2 10 pin 1 27mm Infineon DAP2 Wide Debug Adapter IC50164 22 pin ERF...

Page 16: ...evice The object of declaration described above is in conformity with the relevant Union harmonization legislation EMC directive 2014 30 EU and RoHS directive 2011 65 EU The following harmonized standards and technical specifications have been applied to EN 55032 2012 EN 55024 2010 EN 61000 3 2 2014 EN 61000 3 3 2013 Signed for and on behalf of Schwabhausen 21 March 2017 iSYSTEM AG f Informatiksys...

Page 17: ...User Notes This page is intentionally left blank ...

Page 18: ...User Notes This page is intentionally left blank ...

Page 19: ...User Notes This page is intentionally left blank ...

Page 20: ... information provided in this document at the time of publishing Whilst iSYSTEM reserves the right to make changes to its products and or the specifications detailed herein it does not make any representations or commitments to update this document iSYSTEM All rights reserved ...

Reviews: