Clusters of Home Automation for SGZ805A
Home Automation device feature is defined by the endpoint which contains functional
clusters. Table 1 lists clusters for the endpoint of SGZ805A
Table 1: clusters for the endpoint of SGZ805A
Cluster ID for SGZ805A
Server side
Client side
EP 0X0A (Device ID: Mains Power Outlet (0009) )
Basic(0x0000)
None
Group(0x0004)
Identify(0x0003)
Scene(0x0005)
On/Off(0x0006)
Commission
(
0x0015
)
Meter(0x0702)
Attributes of the
Basic
Information
Identifier
Name
Type
Range
Access
Default
Mandatory /
Optional
0x0000
ZCLVersion
Unsigned
8-bit integer
0x00
–
0xff
Read only
0x03
M
0x0001
ApplicationVersion
Unsigned
8-bit integer
0x00
–
0xff
Read only
0x0B
O
0x0002
StackVersion
Unsigned
8-bit integer
0x00
–
0xff
Read only
0x2D
O
0x0003
HWVersion
Unsigned
8-bit integer
0x00
–
0xff
Read only
0x01
O
0x0004
ManufacturerName
Character
string
0
–
32
bytes
Read only
iSysmart
O
0x0005
ModelIdentifier
Character
string
0
–
32
bytes
Read only
SGZ805AE
3R
O