6. Loading property
Rated Load
Max. Load
Max. Inductive
Max. Load
Max. Surge
Surge
Overload
(
AC
)
Protection
with LEDs
Load
with Electric
Endurable
Detecion
**
with Auto
**Remark**
(
cosφ=0.4
)
Motors
Remark**
Power Cutoff
400W/8
10A/250V
LEDs
8A/250V
1.5HP/250V
150A
YES
Yes
for each gang
This device is not waterproof, after network configuration, place it indoor.
Note
:
1. When measured current is over 10A, the device will cut power within 2 seconds and check if attribute
Bit1(Current OverLoad) level of ACAlarmsMask is 1. If it’s 1 and then device will send Alarm. If it’s 0 and
then device will not send Alarm. When alarm is on, AlarmCluster = 0x0B04, AlarmCode = 0xF0
;
network
indicator flash 10 times (10, 250, 250).
2.
Power data saving chip AT2401 : saving data every 30 seconds.
Power data saving chip AT2402 : saving data every 10 seconds.
Power data saving chip:AT2404/08: saving data every second.
3.
When device is loaded, it would generate peak power (150A) and device would cut off power in 3 seconds. It
will also send alarm warning, AlarmCluster = 0x0B04
,
AlarmCode = 0xEF
;
network indicator lashes 20 times
(20,250,250).