5-5. Power Metering
SGZ825C reports the power consumption data to the ZigBee network.
The related Cluster ID:
Simple Metering Cluster ID (0x0702)
Electrical Measurement Cluster ID (0x0B04)
The related Attribute ID of Simple Metering Cluster ID:
Current Attribute ID: 0xE000; unit: mA
Voltage Attribute ID: 0xE001; unit: V
Power Attribute ID: 0xE002; unit: W
Energy Attribute ID: 0xE003; related to AttributeID CurrentSummationDeliver (0x0000); unit: Wh
The related Attribute ID of Electrical Measurement Cluster ID:
Current Attribute ID: 0x0508
Voltage Attribute ID: 0x0505
Power Attribute ID: 0x050B
Power Factor Attribute ID: 0x0510
The command to reset power consumption summation: 0xE0. The format is:
Bits:8
16
8
8
8
Frame
Manufacturer
Transaction
Command
Frame payload
control
code
Sequence
identifer
Action
number
0x05
0x109F
0xe0
0x00
(clusterid
:
0x0702
,
Action
:
0x00)
5-6. Reset Power Consumption Summation
To reset the power consumption data, please follow the steps:
Step1. Press and hold the Binding Key for 20 seconds. The Network Indicator will flash cyan
5
times
(at
the 3rd, 6
th
, 10
th
, 15
th
, and 20
th
second).
Step2. After releasing the Binding Key, press switch key (Button 1) within 2 seconds. The Network
Indicator will flash cyan once.
5-7. Restore to Factory Setting
To restore it to factory setting, please follow the steps:
Step1. Press and hold the Binding Key for 15 seconds. The Network Indicator will flash
cyan 4
times
(at
3
rd
, 6
th
, 10
th
, and 15
th
second).
Step2. After releasing the Binding Key, press switch key (Button 1) within 2 seconds. The Network
Indicator will flash cyan. After the Network Indicator stops flashing, the restore is completed.