background image

 

control 

code 

Sequence 
number 

identifier 

Count 

NodeID  RSSI 

…  NodeID 

RSSI 

0x05 

0x109F 

 

0x5F 

Byte 

2byte 

Signed 

 

 

 

(Clusterid

0x FE60) 

 

 

5-8. HeartBeat Technique

 

 

In a security system, it is important that Zone devices report the conditions to the central security unit (the  
CIE device). To meet this need, ISysmart came up with a technique called “

HeartBeat

”. 

 

Right after SGZ308 enrolls to a security system, it sends a HeartBeat signal to the CIE device. Afterward, it 
will send HeartBeat data every hour by default settings. 

 
 

5-9. Battery

 

 

When the operating voltage is lower than 2.1V, the indicator will flash 

red 

once

. SGZ308 will send a low-power 

report to the ZigBee network. 
The related data: 

 

Power configuration cluster (ID:0x0001) 

 

Battery voltage attribute (ID:0x0020) 

 
 

5-10. Restore to Factory Setting

 

To restore it to factory setting, please follow the steps: 

Step1. Press and hold the 

Panic Button 

or 15 seconds. 

Step2. Release the button after the indicator shows fast 

red 

flashes. 

Step3. After 10 

red 

flashes, it will go into turn-off mode. The indicator will be Off. 

 

5-11. Offline activation

 

 

If SGZ308 disconnecting from the network, it will wake up every 5 minutes to try re-joined the 
network. It also can manual trigger SGZ308 to re-join the network in the following two ways. 

 

1.

 

Press the panic button 3 seconds and red indicator flash once than device would try re-joined network. 

2.

 

Press the panic button once to alarm and device would try re-joined network. 

Summary of Contents for SGZ308

Page 1: ...iSysmart ZigBeeTM ZigBee Wearable Presence Tag with Emergency Button User Manual ZigBee Wearable Presence Tag with Emergency Button Model SGZ308 ...

Page 2: ...rk 6 5 3 Enroll in the ZigBee Security System 6 5 4 Sleeping Mode 7 5 5 Wake up SGZ308 7 5 6 Panic Button 7 5 7 Presence Tag 8 5 8 HeartBeat Technique 9 5 9 Battery 9 5 10 Restore to Factory Setting 9 5 11 Offline activation 9 6 Home Automation Clusters for SGZ308 10 7 ISysmart App Control Interface 12 8 Related ISysmart Devices 14 9 Important Maintenance Instructions 14 ...

Page 3: ... SGZ308 will send the alarm message to the command center The Warning Device will send out alarm sound or lighting alert for immediate help What is ZigBee ZigBee is a short range wireless transmission technology based on IEEE802 15 4 standard and supports multiple network topologies such as point to point point to multipoint and mesh networks It is defined for a general purpose cost effective low ...

Page 4: ...3 Indicator Red Green Panic Button 2 Product Appearance ...

Page 5: ...tilizes 2 4GHz ISM band up to 16 channels Power supply 1 x CR2450 3 0V battery Operating consumption Tx 33mA Rx 28mA Standby consumption 1 3uA Wireless transmission is up to 200 meters linear distance in open field Easy installation and configuration ...

Page 6: ...5 4 Installation SGZ308 is waterproof ...

Page 7: ...s and hold button for three seconds to search a network to join Step4 The indicator will flash green 5 times after it is joined successfully Otherwise the indicator will not flash Step5 When SGZ308 can not join a network in 3 minutes it will go into off mode To ask for joining Network again press and hole button for 3 seconds After joining a network SGZ308 would try to enroll in the ZigBee securit...

Page 8: ... following steps Step1 Press and hold the Panic Button for 3 seconds Release the button when the indicator flashes red once Step2 The indicator flashes green 5 times when SGZ308 is online Step3 SGZ308 will broadcast the device data to the ZigBee network SGZ308 would be in active status for 2 minutes for communication 5 6 Panic Button SGZ308 s Zone Type Key Fob ID 0x0115 The value of Alarm2 is 1 wh...

Page 9: ...ouble 1 Trouble Failure 0 OK 7 AC mains 1 AC Mains fault 0 AC Mains OK 8 15 Reserved Values of the ExtendedStatus payload ExtendedStatus Attribute Bit Number Meaning Values 0 6 ZoneID 7 ZoneStatusChange Or Heartbeat 1 HeartBeat 0 ZoneStatusChange 5 7 Presence Tag SGZ308 works as a presence tag It is an ideal product to detect one s presence within out of the network coverage for safety purpose SGZ...

Page 10: ... low power report to the ZigBee network The related data Power configuration cluster ID 0x0001 Battery voltage attribute ID 0x0020 5 10 Restore to Factory Setting To restore it to factory setting please follow the steps Step1 Press and hold the Panic Button or 15 seconds Step2 Release the button after the indicator shows fast red flashes Step3 After 10 red flashes it will go into turn off mode The...

Page 11: ...x0001 Identify 0x0003 IAS zone 0x0500 Commissioning 0x0015 Poll Control 0x0020 Diagnostics 0x0B05 This lists the attributes of the basic information Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0x03 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only 0x28 O 0x0002 StackVersion Unsigned 8 bit integer 0x0...

Page 12: ...11 0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0x03 M ...

Page 13: ...12 0x0010 LocationDescription Character string 0 16 bytes Read write O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read write 0x01 M ...

Page 14: ...d device to device list of SGZ308 in ISysmart App and the device information will show up in the management interface as below IAS Zone device The added device EP01 is a Panic Button device type Choose it to enter control interface as below ...

Page 15: ... the button shortly to carry out the emergency alarm Through the following interface of APP setting you can set the Alarm sound after the emergency alarm Choose about device to check device information as below ...

Page 16: ... device in extremely hot temperatures High temperatures may damage the device or battery Do not use or store the device in extremely cold temperatures When the device warms to its normal temperature moisture can form inside the device and damage the device or battery Do not drop knock or shake the device Rough handling would break it Do not use strong chemicals or washing to clean the device Do no...

Page 17: ...ance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the fol...

Reviews: