The module is designed for cabinet installation on a 35mm DIN 
rail according to EN 60715 in corresponding standard housings. 
Extreme environmental conditions impair the function of the pro-
duct.

• 

Protect module from shocks

• 

Use module indoors only

• 

Protect module from humidity

In addition to these safety instructions, you must also observe 
the special safety instructions listed in the individual chapters for 
the individual acts.

2.4. Qualification of staff

Assembly, commissioning, operation, maintenance, decommis-
sioning and disposal may only be carried out by qualified staff. 
Work  on  electrical  parts  may  only  be  carried  out  by  a  trained 
electrician  in  accordance  with  the  applicable  regulations  and 
directives. Other activities in connection with the ISYGLT module, 
such as assembly and installation of system components with 
tested standard plug connections, as well as operation and con-
figuration of the ISYGLT module may only be carried out by trai-
ned staff.

2.5. Changes to the product 

Unauthorized modifications to the ISYGLT module which are not 
described in this or the other applicable instructions can lead to 
malfunctions and are prohibited for safety reasons.

2.6. Use of spare parts and additional equipment

The module may be damaged if unsuitable spare parts and addi-
tional  equipment  are  used.  Only  use  original  spare  parts  and 
additional equipment from the manufacturer.

2.7. Liability notes

SEEBACHER  accepts  no  liability  or  warranty  whatsoever  for 
damage and consequential damage caused by non-compliance 
with  the  technical  regulations,  instructions  and  recommendati-
ons. SEEBACHER shall not be liable for any costs or damage 
incurred by the user or third parties as a result of the use of this 
equipment, in particular improper use of the equipment, misuse 
or malfunction of the connection, malfunction of the equipment 
or connected devices. 

SEEBACHER accepts no liability for printing errors.

2. Safety instructions

Observe  the  following  general  safety  instructions  when  installing 
and commissioning the device:

Assembly and installation of the ISYGLT module may only be carried 
out by a qualified electrician. Other activities in connection with the 
ISYGLT module, such as assembly and installation of system com-
ponents with tested standard plug connections, as well as operation 
and configuration of the ISYGLT module may only be carried out by 
trained staff.

Observe the electrical installation regulations of the country in which 
the device is installed and operated as well as its national accident 
prevention regulations. In addition, observe internal company regu-
lations (work, operating and safety regulations).

Before working on the ISYGLT module system, it must be 
disconnected  from  the  power  supply  and  secured  against 
being switched on again. After completion of the assembly, 
installation and maintenance work, an electrical check must 
be carried out! Check all protective conductor connections 
and the voltages at all connection plugs as well as at each 
individual module slot.

2.1. Intended usage 

The module is exclusively suitable for regulation (control) in con-
nection with ISYGLT system components. Any other use is not 
intended. The limit values stated in the technical data must not be 
exceeded under any circumstances. This applies in particular to 
the permissible ambient temperature range and the permissible 
IP protection type. For applications with a higher required IP pro-
tection type, the ISYGLT module must be installed in a housing 
or a cabinet with a higher IP protection type.

2.2. Predictable mishandling

The module must not be used in the following cases in particular: 

 explosive area 

When operating in explosive areas, sparking can lead to defla-
gration, fire or explosions.

2.3. Safe handling

This module corresponds to the state of the art and the recog-
nised safety regulations. Each device is tested for function and 
safety before delivery.

Only operate this module in perfect condition in accordance with 
the operating instructions, the applicable regulations and directi-
ves of the country in which the device is installed and operated, 
and the applicable safety and accident prevention regulations.

Summary of Contents for 80011171

Page 1: ...w seebacher de Phone 49 0 80 41 77 77 6 Marktstrasse 57 83646 Bad T lz info seebacher de Fax 49 0 80 41 77 77 2 1 Technical Data Instruction Manual MA IP 2 Article no 80011171 IP Master Module with Et...

Page 2: ...e handed over to the device operator The operator will store the documents so that they can be made available if necessary 1 2 Symbols used Observe the following safety and other instructions in the m...

Page 3: ...rrors 2 Safety instructions Observe the following general safety instructions when installing and commissioning the device Assembly and installation of the ISYGLT module may only be carried out by a q...

Page 4: ...screws Assembly site The product can be installed in any position in a casing to be deter mined by the electrician distribution box switch cabinet Observe maximum ambient temperature Assembly steps Re...

Page 5: ...etween several Masters Possible time sources Internal clock not temperature compensated the ISYGLT system clock and DCF 77 radio clock have higher accuracy ISYGLT DCF 77 ISYGLT System clock Time of an...

Page 6: ...voltage This LED lights up when the supply voltage is applied to the module 1 yellow LED SUBNET flashes to indicate a trouble free data transfer on the Subnet 1 green LED RUN STAT indicates the statu...

Page 7: ...ication with modules Interface PROGRAM RS 232 programming interface for connection of PC modem Interface BACKBONE RS 485 potential free for the ISYGLT Backbone BUS for networking several Master module...

Page 8: ...e RxD Programming interface RS 232 RxD receive line NC GND Programming interface RS 232 GND Terminals BACKBONE A BUS A RS 485 B BUS B RS 485 GND GND RS 485 Terminals SETUP TxD Programming interface RS...

Page 9: ...Power supply 90 260V 50 60Hz 24V 2 5A Art no 80030025 L N V V 24V 0V BUS A BUS B N St L St 230V 50Hz Ethernet Programming interface Art no 80011171 ISYGLT Master module RJ45 BACKBONE SETUP PROGRAM SUB...

Reviews: