background image

10

MFM300 TOOLBOX

To update the MFM300 firmware, download new refrigerant data, download snapshot or data 

log information: connect the MFM300 to a PC that has the MFM300 Toolbox application 

installed. To install the MFM300 Toolbox application, go to the Cooper-Atkins website (www.

cooper-atkins.com/downloads.asp), and click on MFM300 Toolbox. The MFM300 Toolbox 

contains the latest firmware and refrigerants available for the MFM300 as well as various data 

logging / management utilities (Contact Cooper-Atkins Corporation for more information).

MFM300 WARRANTY / OBTAINING SERVICE

The MFM300 Instrument is warranted against defects in material or workmanship for 

five (5) years from date of purchase. Cooper-Atkins Corporation will replace or repair the 

defective instrument, at their option, subject to verification of defect. All MFM300 probes and 

accessories are warranted against defects in material or workmanship for one (1) year from 

date of purchase. Cooper-Atkins Corporation has the option to replace or repair the defective 

accessory, subject to verification of defect. These warranties exclude all incidental and 

consequential damages. Some states do not allow the exclusion or limitation of incidental or 

consequential damages, so the foregoing limitation may not apply. Except for the warranty set 

forth above, Cooper-Atkins Corporation, by this disclaimer, gives notice that any statements or 

representations made by it will not create a warranty that this product is fit for any particular 

purpose. Such statements, representations or descriptions are informational only, and are 

not made or given as a warranty of this product in any way. In addition, Cooper-Atkins 

Corporation does not warrant expressly, or by implication, that the electronic instrument will 

meet or comply with the requirements of any safety code or regulation of any country, or any 

municipality, State, Federal or other jurisdiction. Furthermore, Cooper-Atkins Corporation shall 

not be responsible for any loss or damage to customer, directly or indirectly, and whether 

arising in contract or tort. 

MFM300 INSTRUMENT SERVICE INFORMATION

If your MFM300 requires service, send the instrument freight prepaid to Cooper-Atkins 

Corporation. For warranty service, also send proof of date and location of purchase. The 

instrument will be repaired or replaced, at the option of Cooper-Atkins Corporation, and 

returned via least cost transportation.

For non-warranty service, send instrument freight prepaid to Cooper-Atkins. An estimate 

to repair the instrument will be provided before repairs are initiated. The instrument will 

be returned via least cost transportation. There is a 90-day warranty on repaired MFM300 

instruments.

PRODUCT REGISTRY

Please register your 

Cooper-Atkins

 product today. It is the only way to notify you of future  

software / product up-grades. There is no fee to register. Go to:

 www.cooper-atkins.com/

registry.asp

, and complete the on-line form.

Summary of Contents for Cooper MFM300

Page 1: ...MFM300 Multi Function Instrument User Guide and Instrument Warranty...

Page 2: ...te Superheat Sub Cooling 5 Measure Dynamic System Superheat Sub Cooling 5 6 Measure Relative Humidity and Dry Bulb Temperature 6 Display Psychometrics 6 Measure Air Flow 6 Air Balancing 6 Navigate the...

Page 3: ...JACK U1 UNIVERSAL JACK U2 POWER TEMPERATURE JACK T2 TEMPERATURE JACK T1 DOWN ARROW PSYCHROMETRICS PSYCH TEMPERATURE JACK T3 SHIFT SUPERHEAT SUB COOLING SH UP ARROW ENTER REFRIGERANT REF MENU AVERAGE...

Page 4: ...ssage will appear on the display DISPLAY MIN MAX AND AVG VALUES When in Normal Mode press MIN button to display the lowest readings sensed by each probe MAX button to display the highest readings sens...

Page 5: ...memory There is room in the memory for up to five more refrigerants New refrigerant P T data can be downloaded from the Cooper Atkins website www cooper atkins com mfm asp using the MFM300 Toolbox an...

Page 6: ...layed you must enter the shape and size of the duct opening where airflow is being measured To do this press the MENU button while viewing CFM Use the on screen directions to enter the duct shape and...

Page 7: ...Place a temperature probe connected to T1 into an environment with a known temperature and adjust the reading to calibrate and match Zero out probe P1 Zero out probe P2 When a pressure transducer is...

Page 8: ...ace it where temperatures are to be measured Download data Select this menu option to store the Data Logger contents in the MFM300 and view at a later time View data Select this menu option to view th...

Page 9: ...rature Probes Temperature Measurement Range 58 to 302 F 50 to 150 C Temperature Accuracy 0 3F 0 2C or 0 5 of Reading whichever is greater Temperature Display Resolution 0 1 Degree Relative Humidity RH...

Page 10: ...es notice that any statements or representations made by it will not create a warranty that this product is fit for any particular purpose Such statements representations or descriptions are informati...

Reviews: