Proprietary (Configuration) Feature
The Proprietary view demonstrates the capability to change Bluetooth Low Energy connection parameters remotely
via BLETR application.
These parameters only affect Bluetooth Low Energy connections.
1. Max Interval: time (ms) between communication interval between BM77 and Bluetooth LE Central device.
2. Connection Timeout: time (ms) between communication events before a connections considered lost
3. Latency: Number of connection events peripheral (BM77) is allowed to skip
4. Bluetooth LE Name used to advertise Peripheral name to scanning Central devices. Enter new name in text
box and click “Change Name” to invoke change.