Ispring WF150K Installation Instructions & Operating Manual Download Page 9

www.123filter.com

   |   (678) 261-7611   |   

support@123filter.com

  

Page 6 

Before You Start

 

 

 

Warning 

 

 

This system can only be used with 120V/60Hz unidirectional AC power.

 

 

Do not place anything over the power cord and set the unit where the power cord will not be 

stepped on or tripped over.

 

 

Electric shock hazard: Do not overload sockets or extension cords.

 

 

If there is smoke, abnormal odor, or abnormal noise in this machine, immediately unplug the power 

of this system to avoid fire or electric shock.

 

 

Do not touch the plug with wet hands to prevent electric shock.

 

 

 

Note 

 

 

Product installation and use must strictly comply with the requirements of this manual. Do not 

perform any operation on the product without reading and understanding the contents of this 

manual. 

 

Do not use water that is microbiologically unsafe or of unknown quality without disinfection before 

or after use with this system.  

 

Activation of this product indicates that the owner has carefully read, understood and accepted the 

contents of this manual, including the safety notices and instructions. 

 

Failure to operate the product in accordance with this manual may result in product damage, water 

leakage, water seepage, and other losses. 

 

With proper use and maintenance, the lifespan of the wading products manufactured by the 

company is ten years, and 5 years for electronic products, filter materials, wearing pieces (such as 

the seal ring) is one-time use. At that time, the user should stop using the original product or 

component and immediately replace it. 

 
 

 

For questions or concerns, call 

1-678-261-7611 

or email [email protected], or visit

 

www.ispringfilter.com/support. 

 

 

Summary of Contents for WF150K

Page 1: ...WF150K Whole House Central Water Filter INSTALLATION INSTRUCTIONS OPERATING MANUAL Ver 02 2020 Copyright 2005 2020 ISPRING WATER SYSTEMS LLC All rights reserved...

Page 2: ......

Page 3: ...l water filtration systems that purify your water in everyday life to drinking water faucets that deliver pure healthy and tasty water to you and your family At iSpring we strive for high standard pro...

Page 4: ......

Page 5: ...nts User Information 3 Dimensions 4 Product Operation Specifications 5 Before You Start 6 Material Details 7 Installation Installation Requirements 9 Installation Instructions 11 Using the System Prog...

Page 6: ...remaining water from the system Failure of the water supply line or water purifier may result in malfunction damage and possible injury to the enclosure or water supply line In case of malfunction du...

Page 7: ...www 123filter com 678 261 7611 support 123filter com Page 4 Dimensions TOP VIEW SIDE VIEW FRONT VIEW Note all dimensions are in millimeters unless otherwise specified...

Page 8: ...d quality SPECIFICATIONS Model WF150K Hydrostatic Test Pressure 350 psi 24 15 bar Working Pressure Limits minimum maximum 20 125 psi 1 38 8 62 bar Water Temperature Limits minimum maximum 33 8 102 2 F...

Page 9: ...standing the contents of this manual Do not use water that is microbiologically unsafe or of unknown quality without disinfection before or after use with this system Activation of this product indica...

Page 10: ...e included power adapter white box 1 pcs adhered to the base sewage pipe translucent pipe 1 pcs stainless steel braided hose NPT6M connector 2 pcs stainless steel clamps in the PE bag 1 pcs hex key in...

Page 11: ...www 123filter com 678 261 7611 support 123filter com Page 8 5 Bypass Assembly...

Page 12: ...n should be level and the ground bearing capacity should be greater than 300 kg m2 2 Installation Precautions During transportation this product is strictly prohibited from being placed horizontally a...

Page 13: ...upply pipe of this product During installation pay attention to the direction of water flow connect the inlet and outlet pipes according to the inlet and outlet signs and ensure there is no water leak...

Page 14: ...g Check whether the water inlet pipe and sewage pipe are connected as required All piping connections must comply with relevant national standards Fix the sewage hose onto the sewer pipe but do not in...

Page 15: ...er inlet and outlet and prevent the connection pipes from bearing stress The water inlet is connected to the stainless steel braided hose The other end is connected to the water inlet channel The wate...

Page 16: ...filter material washing processes press and hold the keys for 3 seconds in the unlocked state to enter the user menu settings Step 12 b Press SET REGEN button to confirm the parameter setting and ente...

Page 17: ...ediately exit the menu display b SET REGEN While in the unlocked state press and hold the button for 3 seconds to enter the manual regeneration mode You can choose either vacation mode or immediate re...

Page 18: ...SET REGEN to return to the standby state 3 Press and hold MENU for 3 seconds to enter the following user menu settings TIME OF DAY YEAR MONTH DAY Time of day is for normal operation of system and the...

Page 19: ...t metric or gallons SMART CLEAN When set to ON the system will perform a 10 adjustable minute backwash and rinse if there is no water flow detected after 7 adjustable days The regeneration will occur...

Page 20: ...neration time usually in the early morning The regeneration cycle can be set according to time or treated water volume Arbitrarily set the start time of the regeneration process Cycle function program...

Page 21: ...ed Filter High purity copper zinc alloy filter Polyethylene PE liner fiberglass tank Made of synthetic materials light yet strong Corrosion resistance One piece leak proof Granular activated carbon Hi...

Page 22: ...format are available to meet the different customers requirements Multi Language Function English Spanish French and other languages are available Continuous water monitoring Continuous no water monit...

Page 23: ...pped for a while a regeneration operation should be added to ensure the quality of the purified water before reuse If water consumption increases significantly relative to normal usage or the quality...

Page 24: ...bypass valve to the bypass position or close the control valve Control valve failure Contact dealer Poor water quality The Control valve clock is inaccurate due to a power failure causing the regenera...

Page 25: ...is incorrect The control valve is inaccurate due to power failure Adjust the current time of the control valve The regeneration start time is set incorrectly Adjust regeneration start time For operati...

Page 26: ...information from websites other than 123Filter com Amazon Home Depot etc so please be sure to fill in that information upon registration of your system If you have any questions or concerns about your...

Page 27: ......

Page 28: ...Atlanta GA USA iSpringFilter com For questions comments or technical support please contact us at support 123Filter com 678 261 7611 Monday Friday 8 30 a m 5 30 p m EST...

Reviews: