User Information 

 

The user must adhere to the installation specifications described in this Product Installation and 
Operation Manual (hereinafter referred to as the “instruction manual”). iSpring is not responsible 
for damage, loss, or injury resulting from neglect, improper maintenance, or unauthorized 
modification of the unit.  

 

The unit should be placed only on flat surfaces. Do not mount on a wall. 

 

This product is designed for residential use only. Contact iSpring customer service to inquire about 
using in non-residential settings. 

 

The operating temperature range is 33.8°F  –  102.2°F. When the water temperature or ambient 
temperature falls below 33.8°F, shut off the inline water supply, turn off the inline water adapter, 
and drain the remaining water from the system. Failure of the water supply line or water purifier 
may result in malfunction, damage, and possible injury to the enclosure or water supply line. 

 

In case of malfunction due to damage or failure of the power supply system, unplug the system 
immediately and contact iSpring customer service.  

 

If leaking occurs, shut off the inline water supply by turning off the adapter, unplug the system, and 
contact iSpring customer service.  

 

Use only authorized iSpring  parts. Using unauthorized or aftermarket components will void the 
product warranty. 

 

This product is equipped with built-in systems to prevent internal leaks and minimize the risk of 
water damage. However, it is recommended that users check external fittings and connections 
regularly to ensure all components are secure. 

 

Unauthorized modification and disassembly are strictly prohibited and will void the warranty. 

 

Never touch the power cord connector when your hands are wet as this may result in electric shock.  

Summary of Contents for WF150K

Page 1: ...WF150K Whole House Central Water Filter INSTALLATION INSTRUCTIONS OPERATING MANUAL Ver 02 2020 Copyright 2005 2020 ISPRING WATER SYSTEMS LLC All rights reserved...

Page 2: ......

Page 3: ...l water filtration systems that purify your water in everyday life to drinking water faucets that deliver pure healthy and tasty water to you and your family At iSpring we strive for high standard pro...

Page 4: ......

Page 5: ...nts User Information 3 Dimensions 4 Product Operation Specifications 5 Before You Start 6 Material Details 7 Installation Installation Requirements 9 Installation Instructions 11 Using the System Prog...

Page 6: ...remaining water from the system Failure of the water supply line or water purifier may result in malfunction damage and possible injury to the enclosure or water supply line In case of malfunction du...

Page 7: ...www 123filter com 678 261 7611 support 123filter com Page 4 Dimensions TOP VIEW SIDE VIEW FRONT VIEW Note all dimensions are in millimeters unless otherwise specified...

Page 8: ...d quality SPECIFICATIONS Model WF150K Hydrostatic Test Pressure 350 psi 24 15 bar Working Pressure Limits minimum maximum 20 125 psi 1 38 8 62 bar Water Temperature Limits minimum maximum 33 8 102 2 F...

Page 9: ...standing the contents of this manual Do not use water that is microbiologically unsafe or of unknown quality without disinfection before or after use with this system Activation of this product indica...

Page 10: ...e included power adapter white box 1 pcs adhered to the base sewage pipe translucent pipe 1 pcs stainless steel braided hose NPT6M connector 2 pcs stainless steel clamps in the PE bag 1 pcs hex key in...

Page 11: ...www 123filter com 678 261 7611 support 123filter com Page 8 5 Bypass Assembly...

Page 12: ...n should be level and the ground bearing capacity should be greater than 300 kg m2 2 Installation Precautions During transportation this product is strictly prohibited from being placed horizontally a...

Page 13: ...upply pipe of this product During installation pay attention to the direction of water flow connect the inlet and outlet pipes according to the inlet and outlet signs and ensure there is no water leak...

Page 14: ...g Check whether the water inlet pipe and sewage pipe are connected as required All piping connections must comply with relevant national standards Fix the sewage hose onto the sewer pipe but do not in...

Page 15: ...er inlet and outlet and prevent the connection pipes from bearing stress The water inlet is connected to the stainless steel braided hose The other end is connected to the water inlet channel The wate...

Page 16: ...filter material washing processes press and hold the keys for 3 seconds in the unlocked state to enter the user menu settings Step 12 b Press SET REGEN button to confirm the parameter setting and ente...

Page 17: ...ediately exit the menu display b SET REGEN While in the unlocked state press and hold the button for 3 seconds to enter the manual regeneration mode You can choose either vacation mode or immediate re...

Page 18: ...SET REGEN to return to the standby state 3 Press and hold MENU for 3 seconds to enter the following user menu settings TIME OF DAY YEAR MONTH DAY Time of day is for normal operation of system and the...

Page 19: ...t metric or gallons SMART CLEAN When set to ON the system will perform a 10 adjustable minute backwash and rinse if there is no water flow detected after 7 adjustable days The regeneration will occur...

Page 20: ...neration time usually in the early morning The regeneration cycle can be set according to time or treated water volume Arbitrarily set the start time of the regeneration process Cycle function program...

Page 21: ...ed Filter High purity copper zinc alloy filter Polyethylene PE liner fiberglass tank Made of synthetic materials light yet strong Corrosion resistance One piece leak proof Granular activated carbon Hi...

Page 22: ...format are available to meet the different customers requirements Multi Language Function English Spanish French and other languages are available Continuous water monitoring Continuous no water monit...

Page 23: ...pped for a while a regeneration operation should be added to ensure the quality of the purified water before reuse If water consumption increases significantly relative to normal usage or the quality...

Page 24: ...bypass valve to the bypass position or close the control valve Control valve failure Contact dealer Poor water quality The Control valve clock is inaccurate due to a power failure causing the regenera...

Page 25: ...is incorrect The control valve is inaccurate due to power failure Adjust the current time of the control valve The regeneration start time is set incorrectly Adjust regeneration start time For operati...

Page 26: ...information from websites other than 123Filter com Amazon Home Depot etc so please be sure to fill in that information upon registration of your system If you have any questions or concerns about your...

Page 27: ......

Page 28: ...Atlanta GA USA iSpringFilter com For questions comments or technical support please contact us at support 123Filter com 678 261 7611 Monday Friday 8 30 a m 5 30 p m EST...

Reviews: