Step 8: System Start Up (model specific sub-steps are marked with a *)

 

 

* If your model has a UV stage, do not plug in the power until the system has been fully flushed 

 

8.1

  

Make sure no tubings are kinked. 

Turn the Tank Shut-off Valve OFF (perpendicular to the 

yellow tube).

 Place a towel under the system to catch any possible water leaks. 

8.2

  

To prevent any residual carbon from the carbon pre filters from getting into the RO membrane, you 

previously left the tubing to the inlet of the RO membrane housing cap disconnected. Open the 

Feed Water Adapter Valve and Cold Water Supply Valve (CWSV), and flush the first three stages 

into a bucket until the water turns clear. 

8.3

  

Once the water is clear, shut off the Feed Water Adapter and re-connect the tubing to the RO 

membrane housing cap. You will want to flush the system like this whenever the first three stages 

are changed. 

8.4

  

Open the RO faucet. Slowly open the Feed Water Adapter back up and 

check for any leaks

The 

top 3 causes of leaks

 are 

1

) The tubing is not fully inserted into the quick-connect fitting.

 2

The O-ring is not in the correct place or is kinked.

 3

) The Housing/Cap is not tightened properly or 

misaligned with the threads. 

8.5

  

Within 5 minutes, RO water will start slowly trickling from the faucet. Let the faucet trickle for at 

least 15 minutes to flush out the entire system apart from the tank. The water may appear black due 

to loose carbon from new carbon filters. It will eventually turn clear apart from many tiny air 

bubbles leaving the system. 

8.6

  

Shut off the RO Drinking Faucet. Turn on the Tank Shut-off Valve. Wait for the tank to fill up 

completely. It will take 1.5 to 2.5 hours depending on your water temperature (40F-100F, the 

warmer the faster), water TDS (up to 750, the lower the faster), and incoming water psi (45-70, the 

higher the faster). 

8.7

  

After the tank is full, open the RO Drinking Faucet to drain the tank completely. Do not use the 

first tank of water. Let it drain into the sink until the stream turns back to a trickle - this means the 

tank has emptied and you can close the RO faucet to let it begin filling again. 

8.8

  

*

 If your system has a UV filter, plug in the UV power and check to make sure the UV light is 

turning on when water flows through it. The UV filter has a Flow Sensor Switch that detects water 

flow and only turns the light on when needed. If the UV is not turning on when water flows through, 

confirm the power source you are using has power. Typically the garbage disposal outlet only has 

power when the disposal is switched on. 

8.9

  

The TDS (total dissolved solids) of the water should be tested periodically to verify that the system 

is performing properly. 

8.10 

 

Check for leaks daily for the first two weeks after installation to ensure the system is functioning 

properly. Install the included Flood Alarm to provide additional peace of mind and protection. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for RCC100P

Page 1: ...iSpring Reverse Osmosis Water Filtration Systems INSTALLATION INSTRUCTIONS OWNER S MANUAL Ver 11 2018 Copyright 2005 2017 ISPRING WATER SYSTEMS LLC All rights reserved...

Page 2: ...yday life to drinking water faucets that deliver pure healthy and tasty water to you and your family iSpring strives for high standard products and aims to make excellent drinking water accessible for...

Page 3: ...the Drain Saddle 8 Step 4 Installing the Vertical Filters Stages 1 2 and 3 9 Step 5 Installing theTank Shut Off Valve 9 Step 6 Installing the Reverse Osmosis Membrane 9 Step 7 Tubing Hook Up 10 Step...

Page 4: ...en end wrench or adjustable wrench pliers Phillips head screwdriver Scissors or utility knife Operating conditions Minimum water pressure 45 PSI otherwise a booster pump is necessary to raise the inco...

Page 5: ...r 4 Color Tubing Set Drain Saddle Tank Valve Housing Wrenches Leak Stop Valve Spare O Rings and Fittings Real package quantity may vary If your system is a 6 stage or 7 stage system with an Alkaline D...

Page 6: ...sleeve pops out of the fitting when doing this simply pop it back in 4 Insert the tube into the fitting until you reach the mark on the tube You will feel resistance when the tube reaches the small r...

Page 7: ...ium drill bit for steel Do NOT use a hammer drill on nature stone glass and ceramic 3 An indent should be made with a punch on steel before drilling to help guide the bit 4 Use caution when drilling o...

Page 8: ...ead strength does not decay over the years Note Steps 1 7 are independent and can be performed in any order Step 1 Installing the Feed Water Adapter The bushing can convert 3 8 comp to NPT 1 1 Turn of...

Page 9: ...ecurely into the faucet stem then lock it in place by sliding the blue clip under the collet 2 5 Insert the BLUE tubing about 1 2 inch into the push in fitting and again secure it with the blue clip S...

Page 10: ...to install the GAC and CTO filters Note the second stage GAC is the only filter that must go in a certain direction Make sure the end with the rubber washer faces up thereby attaching it to the housin...

Page 11: ...igures 8 and 9 This is very important to avoid leaking and damage to the O ring 6 6 Place the membrane housing cap back on and hand tighten it then use the housing wrench to tighten it another of a tu...

Page 12: ...elbow fitting Models with UV AK DI RO water flows out of point G at FT15 and flows into the input left side of the next stage So the BLUE tubing should be connected to the output side of the final st...

Page 13: ...15 minutes to flush out the entire system apart from the tank The water may appear black due to loose carbon from new carbon filters It will eventually turn clear apart from many tiny air bubbles leav...

Page 14: ...ge it will expand and shut down the feed water Before connecting the tubing into the fitting make sure the end of the tubing is cut square and not damaged or scratched Replace expanded pulp Congratula...

Page 15: ...tem will work properly for years to come See the chart below for the filter pack model numbers for your system The filter packs can be found on 123filter com Amazon or HomeDepot com System Model 1 Yea...

Page 16: ...lter housing off without removing the system from the wall Otherwise you will need to pull the system out lay it down and remove the housings at that point Be careful with the tubing connections when...

Page 17: ...ed on the end of the membrane housing as shown in the previous images We recommend replacing the O ring every 3 years to prevent leaking due to an expired or dried out O ring 8 Place the membrane hous...

Page 18: ...tasting water If you choose to hook up the system to your refrigerator output it can take the place of primary output over the RO faucet Section 2 Knowledge Base and FAQ What Is Reverse Osmosis Rever...

Page 19: ...ium 97 Bicarbonate 95 96 Iron 98 99 Silica 85 90 Boron 50 70 Lead 96 98 Silicate 95 97 Bromide 93 96 Magnesium 96 98 Silver 95 97 Cadmium 96 98 Manganese 96 98 Sodium 92 98 Calcium 96 98 Mercury 96 98...

Page 20: ...e the quality of the RO water with your original source water and also periodically check the RO water to know when it s time to change the filters Maximum distance from tank to faucet We recommend st...

Page 21: ...centrated in this water How to check and adjust the tank pressure if needed When empty the tank pressure should read between 7 and 10 PSI The tank bladder comes pre pressurized so there is no need to...

Page 22: ...the tubings are inserted into the fittings a The tubing is not pushed in past the O ring inside the fitting therefore not creating a seal Make sure the tubing is pushed in a full 5 8 into the fitting...

Page 23: ...rain line will be trickling during this time If the drain line continues to run for 4 hours one of the following reasons could be the problem b Incoming water pressure is below the minimum required le...

Page 24: ...ect elbow fittings used on the system except for on the membrane housing and cap tubing connection and NPT male thread Elbow Fittings on Membrane Housing 4042K Quick connect elbow fittings used on the...

Page 25: ...ive caps Stage 1 See Through Sediment Filter Housing HC12 Transparent stage 1 housing that holds the sediment filter The see through housing allows for the sediment filter to be visually inspected Sta...

Page 26: ...nation of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Warranty does not cover any Manufacturer supplied...

Page 27: ...om Amazon Home Depot etc so please be sure to fill in that information upon registration of your system If you have any questions or concerns about your product please do not hesitate to call or email...

Page 28: ...261 7611 Support 123Filter com 3020 Trotters Parkway Alpharetta GA 30004 USA 123Filter com For questions comments or technical support please contact us at support 123filter com 678 261 7611 Monday F...

Reviews: